3-5. Version Numbers of a Controller
Be sure to use the following combination of the controller version numbers when using the magnescale
that supports the SIEMENS DRIVE-CLiQ.
SINUMERIK soft ware version : 4.4SP2 or later
SINAMICS fi rmware version
Th e functions of the controller may be restricted with any combinations other than the above.
As for details of the versions and functions of the controller, contact SIEMENS.
4. Output Signal
4-1. Signal Specifi cation
Th is product performs data communication with the controller using the SIEMENS DRIVE-CLiQ
protocol.
Moving the scale head in the direction of the arrow gives an addition. (polarity +)
4-2. Controller Connection Specifi cations
Communication circuit side
When connecting to a controller, be sure to follow the connection procedure of the controller manufacturer.
(See "3-4. Wiring Connections with a Controller")
5. Power Supply
Th e power is supplied from the controller that supports the SIEMENS DRIVE-CLiQ (See Section 3-5.
"Version Numbers of a Controller.")
Only a model that supports DRIVE-CLiQ is compatible.
SR27A-AZ Series, CH22 Series
: 4.4SP1 or later
Fig. 4-1
13
(E)