OPTEX i-OneX T Quick Setup Guide
For detailed information, please refer to the installation manual supplied with each sensor
and notes please refer to the i-OneX T Connection Matrix.
Sensor Mounting Location
Header
Use supplied Mounting Template.
Place template so that it is in the
center of the clear door opening
and so that the bottom of the tem-
plate is between 1/4" and 2" from
the bottom edge of the header.
Remove Cover
Remove the cover
Screw driver
Cover locking
tabs
Dipswitch Settings
Dipswitch 3
Frequency
Dipswitch 4
Dipswitch 5
BLUEZONE™
Dipswitch 13
Direction
Dipswitch 14
Simultaneous output
Dipswitch 15
Safety Output (to door controller)
Dipswitch 16
Safety Input (from door controller)
Dipswitch 18
Installation Mode
Adjusting the Pattern Width
Left eliminated
Right eliminated
1
2 3
7 8 9
Width adjustment screws
Align with center of clear door opening
2"
1/4"
Insert
1
Screw driver
Slide forward to
2
remove cover
Setting 1
Setting 2
Setting 3
3 4
3 4
OFF
ON
5
5
Bi
Uni
13
13
OFF
ON
14
14
N.O.
N.C.
15
15
High
Low
16
16
OFF
ON
18
18
1 2 3
Opens all
Opens all
elimination
areas
areas
1 2 3 4 5 6 7 8 9
(continue other side)
Drill (2) 1/8" holes and (1) 5/16" hole as indi-
cated on the template. Remove template from
header. Remove the cover from the sensor.
Fasten the sensor securely to the header
using the supplied screws (do not over-torque
screws or sensor body may distort).
.
Setting 4
When using more than one sensor close to each other,
set the frequency different for each sensor
3 4
3 4
When dipswitch 5 is set to "ON", the BLUEZONE (1st row)
is active and looks through the threshold.
When dipswitch 13 is set to "Uni", this enables the door to
close faster when a person walks away from the door.
When dipswitch 14 is set to "ON", both the activation &
safety relay outputs will operate simultaneously regard-
less of detection area. But only the Safety ouput relay
will respond back with a Safety output when it receives a
Safety input.
Select "N.O."/"N.C." for Safety output.
The delay time between Safety input and Safety output is
10 msec.
Set dipswitch 18 to "ON" to adjust the 2nd row. During the
installation mode only the 2nd row remains active and the
operation indicator shows yellow. After setting the row, turn
dipswitch 18 "OFF".
The width of the Approach area can be adjusted
by changing Dipswitches 8-10 as shown below.
Dipswitches
7 8 9
elimination
1 2 3 4 5 6 7 8 9
8
9
10
1 2 3 4 5 6 7 8
1
2
3
6
4 5
Active area
Inactive area
8
7

Advertisement

loading

Summary of Contents for Optex i-OneX T

  • Page 1 OPTEX i-OneX T Quick Setup Guide For detailed information, please refer to the installation manual supplied with each sensor and notes please refer to the i-OneX T Connection Matrix. Sensor Mounting Location Header Drill (2) 1/8” holes and (1) 5/16” hole as indi- Use supplied Mounting Template.
  • Page 2 Perform walk test procedure to verify substantial compliance with ANSI/BHMA A156.10 section 8. 18730 Wilmington Ave, Unit 100 OPTEX Technologies Inc. OPTEX Technical Support (800) 877-6656 Rancho Dominguez, CA 90220 (East Coast Office) East Coast: Perry Watkins, Ext. 220 Ph 310 214-8644 8510 McAlpine Park Dr.