13.2.4 Detector Function Test

dt Verifies that an infrared detector is connected to each channel.
Press the SELECT button until dt is displayed.
Press the TEST button for one second.
o The HIGH LED will illuminate for each channel that has a detector(s), connected.
o The indicator will flash for five seconds.
This function only applies in Infrared operation.
This test only confirms that a detector is connected to the channel.
o See the detector noise level reading in the On-site software for a comprehensive evaluation
of the health of the detector.

13.2.5 IP Address Reset

IP Resets the IP address back to the factory default setting
Press the SELECT button until IP is displayed.
Press and hold the TEST button for 5 seconds.
o IP will flash when the reset has occurred.

13.2.6 Password Override

PS Activates password override. This is used if the password has been lost. Once the password has been
shut off, the user may change the password using the On-site or CMS software.
Press the SELECT button until PS is displayed.
Press and hold the TEST button.
o PS will flash when the override has occurred.
o The password will be shut off for 1 hour or until the phase selector is reset.

13.2.7 Erase Logs

EL Erases all of the logs on the phase selector. This includes call logs, diagnostic logs and call playback logs.
Press the SELECT button until EL is displayed.
Press and hold the TEST button for 5 seconds to erase all logs.
o EL will flash when the erase has occurred.

13.2.8 Reset All Parameters to Default

rd Resets all configurable parameters for the phase selector to factory default.
Press the SELECT button until rd is displayed,
Press and hold the TEST button for 5 seconds.
o rd will flash when the reset has occurred.

13.2.9 Standby Mode

sb Places the phase selector into standby mode. In this mode the phase selector remains powered on but it
will not respond to preempt requests from vehicles. Manual test calls will also be ignored while in standby
mode.
Press the SELECT button until sb is displayed.
Press and hold the TEST button for 5 seconds.
o sb will flash and remained displayed until the phase selector returns to normal operation.
Return to normal operation
With sb displayed, Press the TEST button.
o sb will flash and then go off when you have returned to normal operation.