Additional Output Connections - OPTICOM 764 Installation Manual

Gps system phase selector
Table of Contents

Advertisement

9.5 Additional Output Connections

If an Opticom™ System Phase Selector requires more than 4 outputs, it is necessary to make additional
connections between the auxiliary interface panel (AIP) and the traffic control cabinet wiring. Outputs for
the Time Sync output function are also available on the AIP. See the On-site software help file for details.
Table 9-1 shows the function of the auxiliary interface panel outputs for the various modes of operation.
1. Determine the appropriate length of the wires required to connect the auxiliary interface panel to the
wiring points in the traffic control cabinet.
2. Strip 1/4 inch of insulation from both ends of the wires being used.
3. Insert one end of each wire into the desired terminal of the auxiliary interface panel and tighten the
screw.
4. Repeat step 3 for all desired connections.
5. Route the wires through the traffic control cabinet. Install spade lugs on the wires.
6. Insert one wire at a time into the correct terminal and tighten the screw.
7. Verify that your wiring is correct, and the connections are tight.
8. Use the configuration software to make the appropriate assignments for the outputs.
9. When using any output on the auxiliary interface panel you must make a connection between one of
the Logic Common terminal on the auxiliary interface panel and the logic common terminal on your
controller. If you do not make this connection the auxiliary interface panel outputs will not work.
Intersection Equipment Installation Instructions
Figure 9-5 Connecting existing Harness/AIP cable