Debounce time

In coin mode, the debounce time for
the minimum payment signal that
must be applied can be adjusted.
– Factory setting: Short
For coin boxes where the falling coin
generates the paid pulse.
– Long
For central control units on a 230 V
basis.

Pay system override time

Setting the transition signal for the
coin box. Security time margin to pre-
vent the coin box being tampered
with.
The override time can be set or
switched off in increments of one
minute from 30 minutes up to four
hours.
If the programme does not end within
the override time, the coin box setting is
reset. The programme is cancelled.
Factory default: 3 hours
Supervisor level

Duration Cool air

The running time can be adjusted.
A time of between 10 minutes and
2 hours can be set in five-minute inter-
vals.
Factory default: 2 hours

Duration Warm air

The running time can be adjusted.
A time of between 20 minutes and
2 hours can be set in five-minute inter-
vals.
Factory default: 2 hours

FOC programmes

In coin mode, you can decide whether
the Timed drying cool air programme
can be used for free.
– Factory default: Off
– On