Recharge the machine fully after its last use. Do not leave the machine in a discharged state.
Under abnormal use; i.e. leaving the machine without charging for a period of time, we advise that you disconnect the battery from the machine. If the machine will be standing unused for a period of
30 days or more, then batteries must be fully charged.
Note: Batteries should be recharged every three months. Charge fully the day before you start using the machine again.
Under normal daily usage: Recharge batteries after each use regardless of machine operation time. Connect the charger unit to the battery and plug the charger into a suitable power supply.
Signal (LED)
Red LED on
First phase (constant current mode)
Yellow LED on
Second phase (constant voltage mode)
Green LED on
Third phase (constant voltage mode) charge completed
Safety timer exceeded
Red LED flashing
Internal short circuit
Battery not connected
Yellow LED flashing
Output short circuit
Unsuitable Battery
The battery charge level meter displays the charge level of the batteries; when fully charged, all meter lights are illuminated.
As the machine is used and the batteries are discharged, the battery charge level meter lights will go out from top to bottom.
If the battery charge level is allowed to discharge to the point that only one red light remains illuminated, the operator should charge the battery.
The battery supplied for this machine allows for a run time of 45 mins approx (Hi Mode), when fully charged.
The battery pack must be fully discharged and recharged over a few cycles and brushes need to be worn in to achieve maximum efficiency.
Charge time for a fully discharged battery, is approximately 6 hours.
The TTB 1840 come with its own stand-alone charger.
Connect the charger to a suitable power supply.
Once mains power is connected the red charging indicator will illuminate. To ensure a full charge, the battery should be left for a period of 6 hrs.
Once fully charged, disconnect the charger from the power supply and the charger lead from battery.
Note:
Your charger will need resetting between subsquent battery charging, remove the charger from AC power supply to reset.
Please comply with your company's COSHH risk assessments
(Make sure you wear the appropriate safety clothing).
Open the separator and let the machine air dry...
Only leave the machine resting on the brush and floor tool for short periods of time...
Regular Maintenance...
Battery Charging ... (Cont)
Use recommended PPE as required...
Leave the machine empty and clean...
assistance contact your supervisor
Meaning
Numatic International
Chard, Somerset. TA20 2GB
If you require further training or
Manufactured by
01460 68600
MED-000610 05/17 (A02)

Advertisement

loading

This manual is also suitable for:

Floorcare tt 1840