1
Unscrew the four knobs securing the
blade holder (Fig.1).
Fitting Brush - Floor Tool, Filling Machine, Fill Gauge, Moving
Draining Top Tank, Draining Bottom Tank, Clean Water Filter
Regular Maintenance...
Changing the Floor Tool Blades ...
B
2
Remove the blade holder (Fig.2).
Refitting the Floor Tool Blades
Refit the blade holder, retain using the two outer knobs.
Ensure the slotted blade goes to the front of the floor-tool.
Refit the floor-tool using the two central knobs to the floor-tool.
NOTE: The blades are designed to be reversible, thus extending their useful
working life.
Clean Separator
To change the floor-tool, firstly swing the
floor-tool clear of the machine. Undo the
two floor-tool retaining knobs (Fig.A).
Pull the floortool away from the machine
(Fig.B).
3
Replace the Squeegee blades using
(903531) replacement blade set (Fig.3),
fitting the blades on to the moulded
location lugs.
Water Flow Adjustment, Raising the Floor Tool
Changing the Floor Tool Blades
If you require further training or
assistance contact your supervisor
1
2
3
4
Floor Tool Overview
1. Retaining knobs x 4
2. Front blade (slotted)
3. Blade carrier
4. Rear blade
5. Floor tool main body
Operating Switches
Removing Battery, Fuse, Charging
5
Charging (Cont)