The 1840 has been designed to scrub and dry a variety of hard floors.
This machine has not been designed to pick up large objects, make sure you pre-sweep the floor before use.
For optimum performance make sure you keep the filters, hoses and floor tool blades clean and free from debris.
Disconnect from the power supply or remove the battery BEFORE commencing maintenance or cleaning of your machine.
PROBLEM
CAUSE
Machine will not operate.
Missing or blown fuses.
Battery not connected.
Low battery charge.
Vacuum will not operate.
Vacuum not turned on.
Poor water pick-up.
Waste-water tank full.
Blocked vacuum hose.
Loose hose.
Basket filter blocked.
Separator filter blocked.
Poor separator seal.
Damaged separator seal.
Damaged vacuum hose.
Damaged floor-tool blades.
Low battery charge.
No brush / Scrub function.
No brushes fitted.
Brush overloaded.
Little or no water flow.
Clean-water tank empty.
Clean-water tank filter blocked.
Incorrect water flow setting.
Machine just 'stops' while
To much load on the brush system.
operating.
Blown fuse in battery pack.
It is recommended you strip and
thoroughly clean the machine and its
components regularly.
At least weekly to avoid operating
troubles and machine breakdowns.
Fitting Brush - Floor Tool, Filling Machine, Fill Gauge, Moving
Draining Top Tank, Draining Bottom Tank, Clean Water Filter
Trouble Shooting and Help Guide
TT / TGB 1840
SOLUTION
Replace
fuse.
Connect Battery.
Charge.
Turn on.
Empty.
Clean.
Tighten.
Clean.
Clean.
Clean and refit.
Renew.
Renew.
Renew.
Recharge.
Check and fit.
Reset.
Fill.
Clean.
Adjust tap as desired
Reset, decrease the brush load.
Replace 40 Amp fuse.
Clean Separator
Changing the Floor Tool Blades
The machine should be left in a clean and tidy state, drain
Water Flow Adjustment, Raising the Floor Tool
Removing Battery, Fuse, Charging
Make sure you read and fully
understand your 1840 manual
before using the machine.
After every time the machine is used.
all fluids, clean all filters, pipes and place the
battery on charge.
Operating Switches
Charging (Cont)

Advertisement

loading

Summary of Contents for Numatic FloorCare TGB 1840

  • Page 1 Trouble Shooting and Help Guide Make sure you read and fully FloorCare understand your 1840 manual TT / TGB 1840 before using the machine. The 1840 has been designed to scrub and dry a variety of hard floors. This machine has not been designed to pick up large objects, make sure you pre-sweep the floor before use. For optimum performance make sure you keep the filters, hoses and floor tool blades clean and free from debris.
  • Page 2 Fitting Brush - Floor Tool, Filling machine, Fill Gauge, Moving... Index page... Fitting the brush... Fitting the Floor Tool... The machine uses a 400mm brush or a Fit the brush pad onto the Nulock drive Swing the floor-tool carrier to the side of the Make sure the inspection cap is in place on the machine.
  • Page 3 Water Flow Adjustment and Raising the Floor Tool... Index page... Water Flow Adjustment... Raising and lowering the Floor Tool... Located on the left of the machine is the clean Ideally set the tap to 45% this enables the To raise and lower the floor tool make sure the Lift the handle near the base of water tap, make sure the tap has been turned cleaning solution to last the same time as a fully...
  • Page 4: Operating Switches

    Operating Switches Index page... Whilst the brush motor is running press the water flow On / Off Button for fluid control (Fig.C), the clean water On / Off tap must be open. Ideally set the tap to 450 this enables the cleaning solution to last the same time as a fully-charged battery. When the Triggers are released the brush motor and the cleaning solution pump will switch off, the vacuum motor will continue for 10 seconds.
  • Page 5 Regular Maintenance... Index page... Drain Top (Waste) Tank Drain Bottom (Clean Water) Tank The clean-water tank can be drained via the yellow cap fitted to the left hand side of the machine. There is a sealing bung beneath the yellow cap (ensure the sealing bung is clean) The cap should only be done up by hand.
  • Page 6 Make sure your hoses are in good order, secure and free from debris. Storage ... Numatic recommend you leave your 1840 resting on the brush if leaving your machine for short periods of time. This saves distorting the squeegee blades.
  • Page 7 Regular Maintenance... If you require further training or Index page... assistance contact your supervisor Changing the Floor Tool Blades ... To change the floor-tool, firstly swing the floor-tool clear of the machine. Undo the two floor-tool retaining knobs (Fig.A). Pull the floortool away from the machine (Fig.B).
  • Page 8 Removing the Battery Pack Fuse ... The battery pack comes fitted with a 40 amp safety fuse. Replace the fuse using (208526) Numatic approved part Battery Charging ... Recharge the machine fully after its last use. Do not leave the machine in a discharged state.
  • Page 9 (Make sure you wear the appropriate safety clothing). Leave the machine empty and clean... Manufactured by Numatic International Open the separator and let the machine air dry... Chard, Somerset. TA20 2GB Only leave the machine resting on the brush and floor tool for short periods of time...