Coding Code 1 - Viessmann VITOPEND 200 Installation And Service Instructions Manual

Gas fired combi boiler
Table of Contents

Advertisement

Coding
Code 1
Calling up code 1
Note
On weather‐compensated control
units, codes are displayed as plain
text. Codes which are irrelevant (due
to the system equipment level or the
setting of other codes) will not be dis-
played.
For heating systems with one heating
circuit without mixer and one heating
circuit with mixer, initially the possible
coding addresses A0 to d4 are
scrolled for the heating circuit without
mixer A1, then those for the heating
circuit with mixer M2.
Press the following keys:
1. K + L simultaneously for
approx. 2s.
Overview
Coding
Coding in the delivered condition
System designs
00:2
System version 1, 3:
1 heating circuit without
mixer A1, with DHW
heating
50
2. a/b
for the required coding
address; the address
flashes
3. d
to confirm
4. a/b
for the selected value
5. d
as confirmation; the dis-
play briefly shows
"accepted" (weather‐
compensated control
unit); the address flashes
again.
6. a/b
for the selection of further
addresses.
7. K + L simultaneously for
approx. 1 s to terminate
code 1.
Possible change
00:4
1 heating circuit with
mixer M2, with DHW
heating
00:6
System version 2, 4:
1 heating circuit without
mixer A1 and 1 heating
circuit with mixer M2, with
DHW heating