Coding
Code 1
(cont.)
Coding in
Function mode
the as
delivered
condition
Address:
value
Gas type
1E:0
Natural gas operation,
defaulted by the boiler
coding card
Venting/filling
2F:0
Venting program dis-
abled
User no.
77:1
LON user number
DHW priority A1
A2:2
DHW cylinder priority
applicable to heating
circuit pump and mixer
DHW priority M2
A2:2
DHW cylinder priority
applicable to heating
circuit pump and mixer
Summer econ. A1
A5:5
*
1
With heating circuit
pump logic function
*1
Only for weather-compensated control units.
40
Coding
Possible change
change
Address:
value
1E:1
LPG operation, defaulted
by the boiler coding card
2F:1
Venting program enabled
2F:2
Filling program enabled
77:2
LON user number, adjus-
to
table from 1 to 99:
77:99
1 - 4 = boiler
5 = cascade
10 - ... = Vitotronic 050
99 = Vitocom
Note
Allocate each number
only once.
A2:0
Without cylinder priority
for heating circuit pump
A2:0
Without DHW cylinder
priority applicable to
heating circuit pump and
mixer
A2:1
DHW cylinder priority
only applicable to mixer
A2:3
Modulating DHW cylinder
to
priority
A2:15
A5:0
Without heating circuit
pump logic function