Setting The Maximum Output - Viessmann VITOPEND 200 Installation And Service Instructions Manual

Gas fired combi boiler
Table of Contents

Advertisement

Initial start-up, inspection, maintenance
Further details regarding the individual steps
Rated output
44.6 MJ/m
LPG
21.3 kWh/m
76.8 MJ/m
10. Snap cap B into place.
11. Check the setting values and
record them in the service report.
12. Press d.
Operation with the lower rated
output is terminated.
13. Switch OFF the system at the
control unit (the boiler shuts
down), close the gas shut‐off
valve, remove the pressure gauge
and close test port A with the
screw.

Setting the maximum output

Note
The maximum output can be limited for heating operation. You can limit the
output via the modulation range.
1. Start up the boiler.
*1
Only for DHW heating
28
3
3
50
0.89
3
14. Open the gas shut‐off valve and
2. K + F press simultaneously:
a/b
d
(cont.)
kW 10.5
mbar
3.3 14.8
start the boiler.
Danger
Gas escaping from the test
port leads to a risk of
explosion.
Check test port for sound-
ness.
"100" flashes on the dis-
play (corresponds to
100% of rated output)
and "A" is displayed.
On weather‐compen-
sated control units, the
display additionally
shows "Max. output".
press for the required
value in % of rated output
as max. output
press to confirm
24
*
1
29
22.6