Viessmann VITOPEND 200 Installation And Service Instructions Manual page 81

Gas fired combi boiler
Table of Contents

Advertisement

Fault codes
(cont.)
Display
Const.
Weath.‐
fault
comp.
code
30
X
X
38
X
X
40
X
48
X
50
X
X
51
X
X
58
X
X
59
X
X
A7
X
b1
X
X
System char-
Cause
acteristics
Burner
Boiler water
blocked
temperature
sensor
shorted out
Burner
Boiler water
blocked
temperature
sensor lead
broken
Mixer closes
Mixer circuit
M2 flow tem-
perature
sensor
shorted out
Mixer closes
Mixer circuit
M2 flow tem-
perature
sensor lead
broken
No DHW heat-
Comfort sen-
ing
sor shorted
out
No DHW heat-
Outlet tem-
ing
perature
sensor
shorted out
No DHW heat-
Comfort sen-
ing
sor lead bro-
ken
No DHW heat-
Outlet tem-
ing
perature
sensor lead
broken
Regulated op-
Faulty pro-
eration as per
gramming
delivered con-
unit
dition
Regulated op-
Communica-
eration as per
tion error
delivered con-
program-
dition
ming unit
Troubleshooting
Remedy
Check the boiler
water tempera-
ture sensor (see
page 91)
Check the boiler
water tempera-
ture sensor (see
page 91)
Check flow tem-
perature sensor
Check flow tem-
perature sensor
Check sensors
(see page 91)
Check sensors
(see page 91)
Check sensors
(see page 91)
Check sensor
(see page 91)
Replace program-
ming unit
Check connec-
tions and replace
the programming
unit, if required
81