Line regulation:
The output line regulation for each output is less than ±1%, when
measured at each output's respective rated load and under ±10%
changing input voltage conditions.
Load regulation:
The values for each of the following output numbers were obtained
by changing each output load ±40% from the 60% rated load,
whilst simultaneously keeping all other outputs at 60% of their
respective rated loads.
Table B-6: 24 V
Output No.
1
2
3
4
Power good signal:
When the power is turned on, the power good signal will activate
100 to 500 ms after all output DC voltages are operating within
their respective regulation limits.
Power fail signal:
This will activate at least 0.5 ms before any of the output voltages
fall below their respective regulation limits.
68
AWS-825B/PB User's Manual
power supply load regulation
DC
Load regulation
±4%
±5%
±3%
±3%

Advertisement