Power good and power fail signals (optional):
When the power is turned on, the power good signal will activate
100 to 500 ms after all output DC voltages are operating within
their respective regulation limits.
The power fail signal will activate at least 1 ms before the +5 V
output voltage falls below its regulation limit.
Short circuit protection:
A short circuit placed on any output to ground is shut down. When
the short circuit conditions have ceased to exist, power will then be
recycled to restart the power supply.
Over-current protection:
The power supply will shut down all the DC outputs when any
output is overloaded beyond its current limit or beyond its nominal
line voltage limit. When the over-current conditions have ceased to
exist, power will then be recycled to restart the power supply.
Current limit ranges:
Over-voltage protection:
The power supply will shut down all the DC outputs when any
output maximum voltage limit is exceeded. When the over-voltage
conditions have ceased to exist, power will then be recycled to
restart the power supply.
Voltage limit ranges:
64
AWS-825B/PB User's Manual
5 V:
32 ~ 45 A
12 V:
13 ~ 20 A
-12 V: 6 ~ 12 A
-5 V:
1.5 ~ 3 A
5 V:
6.25 ±0.75 V
12 V:
14 ±1 V
-5 V:
6.25 ±0.75 V
-12 V: 14 ±1 V