Installing Or Replacing A Fan Module: 2076-92F; Sas Cable Correctly Inserted Into The Sas Port - IBM StorVize V7000 Gen2 Quick Installation Manual

Table of Contents

Advertisement

Figure 80. SAS cable correctly inserted into the SAS port

Installing or replacing a fan module: 2076-92F

You can reinstall a fan module or replace a faulty fan module in a 2076-92F
expansion enclosure.
Before you begin
Important: You can replace a fan module without powering off the expansion
enclosure. However, to maintain operating temperature, replace the fan module
within 10 minutes of its removal. When a fan module is removed, the reduction in
airflow through the enclosure might cause the enclosure or its components to shut
down to protect from overheating.
About this task
The expansion enclosure might or might not be powered on, depending on the
number of fan modules that need to be replaced. For example, the expansion
enclosure must be powered off if all four fan modules are removed.
This task assumes that the following condition was met:
v You have removed a fan module, following the process described in "Removing
Procedure
1. Hold the fan module with the release tab on top and the connector pin on the
88
Storwize V7000 Gen2 and Gen2+: Quick Installation Guide
a fan module: 2076-92F" on page 111.
bottom, as shown in Figure 81 on page 89.

Advertisement