11
Figure 57. Comparing the location of the components of the CMA assemblies
5. Install the inner connector of the lower CMA assembly ( 7 ) to the inner
6. Install the outer connector of the lower CMA assembly ( 9 ) to the outer
7. Attach the support rail connector on the lower CMA assembly ( 11 ) to the
8. Route the cables and power cords on the CMA. If needed, secure them with
9. Reconnect the power cords and other cables, as needed.
8
7 Inner connector on lower CMA
8 Connector base on inner rail member
9 Outer connector on lower CMA
10 Connector base on outer rail member
11 Support rail connector the lower CMA
12 Connector base on outer rail member
member of the right support rail ( 8 ), as shown in Figure 57).
member of the right support rail 10 , as shown in Figure 57.
connector on the left support rail ( 12 ), as shown in Figure 57. Ensure the
lower CMA assembly is securely attached to the hooks on the end of the
support rails.
cable ties or hook-and-loop fasteners.
Notes:
v Use the cable straps that are provided on the rear of the system to retain the
cables and prevent them from sagging.
v Allow slack in all of the cables to avoid tension in the cables as the CMA
moves.
Chapter 2. Installing the Storwize V7000 Gen2 and Storwize V7000 Gen2+ hardware