Connect the compressed air supply line
to the compressed air connection of
the filter. Use pipe sealant on all
compressed air connections.
Compressed air components
(accessories, see page. 30)
A shut off valve for service work and a
filter regulator should be installed in the
compressed air pipe line (Note the flow
direction during the installation).
Important! the filter regulator
must be positioned in a frost free
environment.
Recommended connection size:
minimum 1/2".
FilterMax F
Control box
Service valve with
integrated drain valve
(accessory)
COMPRESSED AIR CONNECTION
Pressure switch
(accessory)
Filter regulator,
recommended pressure
0,5 MPa (5 bar / 73 psi)
(accessory)
Compressed air tank, module no. 3
Compressed air tank, module no. 2
Compressed air tank, module no. 1
IMPORTANT!
• The compressed air supply pressure has
to be = 0,4 - 0,6 MPa (4 - 6 bar / 58 - 87 psi).
• The compressed air shall have a dew point
below the minimum temperature at which the
system is ment to be used.
• The compressed air supply must be both oil
and water free.
• Improper air pressure or contamination in
the compressed air can result in cleaning
valve failure, poor cleaning and filter
performance.
• Purge compressed air lines to remove debris
before connecting to the compressed air
manifold.
• Do not use thread-sealing tape after the
filter regulator.
• Quick couplings throttle the air too much
and are not recommended.
• Turn off and bleed off compressed air supply
before doing any service work.
• Do not pressurise the system if the air tem-
perature is below the minimum operating
Compressed
temperature, that is -20 °C. At lower air tem-
air connection
perature the process could be started and be
in operation for a while (approx. 15 min.) after
which the system can be pressurised.
Water drain valve
Water drain valve
Water drain valve
8