Nederman FilterMax F is designed for collecting and
filtering fume and non-explosive dry dust.
To guarantee the correct function and a minimal service
FilterMax F must only be used for these purposes and
according to the instructions in this manual. The manual
contains important warning directions which have to be
read and followed.
Any functional disorders, especially those affecting the
safety of the machine, should be rectified immediately.
PRE-INSTALLATION
FilterMax FI is for indoor installation.
FilterMax FO is for outdoor installation.
FilterMax F should be located with consideration for easy
handling of the collected dust and for convenience of
service and maintenance.
FilterMax F is usually installed on a reinforced concrete
foundation. However, installation on another structure is
also possible. When calculating for foundation or supporting
structure the following factors should be taken into conside-
ration (see technical data):
• Total weight of FilterMax F
• Max. weight of collected contamination
• Possible wind load
• Possible snow load
IMPORTANT! Location must be clear of all obstructions
such as utility lines etc. Pay particular attention to the
anchor bolt location. Anchor bolts (M16) must extend at
least 60 mm above foundation. If you intend to secure the
unit by using expansion bolts or equivalent fittings, the
concrete floor must be prepared accordingly.
TECHNICAL DATA
Filtration
Operating airflow
Filterarea / filter cartridge
Filter material
Operating temperature
Process air (dry) temperature
Material description
Environment classes *
Compressed air requirements
Compressed air consumption
Compressed air connection
Voltage supply
Protection class
Relay voltage, accessory
Working pressure
Pulse noise
Weight
IMPORTANT! SAFETY INFORMATION
Basic PW filter: 99% at 0,3 µm (after some time in operation), BIA class C
PTFE filter: 99,9% at 0,3 µm (after some time in operation), BIA class C
1 module: 2400 - 3600 m
2 modules: 4800 - 7200 m
3 modules: 7200 - 10800 m
2
1 module: 60 m
2 layer polyester / polypropylene
-20°C to +60 °C
0 °C to +60 °C, not condensing
3 mm painted steel (FilterMax FI, FO), epoxy based zinc primer and top coat (FO only))
C2 = low corrosion risk, indoors, unheated air varying temperature (FilterMax FI)
C4 = high corrosion risk, outdoors polluted urban areas and coastal areas (FilterMax FO)
0,6 MPa (6 bar, 87 psi), water and oil free
32 N-litres / cleaning pulse at 0,6 MPa (6 bar, 87 psi)
1/2" R 15, max. 0,6 MPa (6 bar, 87 psi)
100 V, 120 V, 230 V, 50/60 Hz
IP 54
24 V AC, max. 60 VA
0 to -5 kPa, not overpressure
Lp Aeq, 30 s, 50 dB
1 module: 615 kg, 2 modules: 890 kg, 3 modules: 1150 kg
For safe and reliable results assembling
work, electrical installation, use, service
and trouble-shooting should be performed
by qualified personnel. Special training may
also be necessary.
Please contact your nearest authorised
dealer or AB Ph. Nederman & Co. for
technical advice.
1200
3
/h (depending on load and application)
3
/h (depending on load and application)
3
/h (depending on load and application)
2
, 2 modules: 120 m
, 3 modules: 180 m
min. 100
FILTERMAX
1320
2
*according to EN ISO 12944
4
Need help?