WARNING!
Risk of personal injuries
and/or product damages!
Use approved lifting equipment for
unloading, assembly and installation
of the units.
IMPORTANT!
Ensure that the inlet, outlet and
all filter units always are mounted
together with bolts in all intended
holes. Always use toothed washers
to ensure electric connection.
MOUNTING INSTRUCTION
Use schackles,
not hooks on the
lifting sling.
x 3
Connect the lifting sling
to 4 cabinet lifting lugs.
Distribute loads equally.
NB! Maximum 2 units should be
lifted at the same time.
1.
Mount the dust containers. If dust containers
2 x 100 litre should be mounted the stand extensions
also must be mounted.
2.
FilterMax is usually anchored to a concrete foun-
dation with expansion bolts or similar. Fit the fixing bolts
and use adjusting pieces, if necessary, to get the filter
unit in level. Check with a spirit level.
For more stabilty, the filter unit can be braced
against the wall.
3.
For FilterMax F 60 and F 90 two and three
filter units are used respectively. Mount the units
together to build the complete filter unit.
6
Need help?