TROUBLE-SHOOTING SCHEDULE
FilterMax F will not start.
Are there any LED's on the
controlbox panel that are on.
YES
NO
Check the fuses on the card and
the power supply to the card. If
the power supply and the fuses
are fully functional, contact your
nearest Nederman representative
for more assistence.
FilterMax F starts, but stops after
a while and the display shows
Err + a digit.
Is the display showing Err 0 ?
YES
NO
The cable connecting the controller
to the first pilot box is not properly
connected.
FilterMax F starts, but the fan will
not start.
A
Possible faults
Control questions
Actions
Is the A-alarm LED no. 7, on?
NO
YES
Are you trying to remote start
the filter?
NO
YES
Contact your nearest Nederman
representative for advice.
B
Is the display showing Err +
another digit than 0 ?
NO
YES
Contact your nearest Nederman
representative for advice.
C
Check that the electrical wiring
for the fan start is done correctly
between 1 and output common
(10 or 11) on the outputs (block
JP6). See wiring diagram, page 13.
IMPORTANT!
• Turn off the compressed air
supply with the service valve
before doing any work on the
cleaning system.
• Do not pressurise the system
if the air temperature is below
the minimum operating tem-
°
perature (= -20
C). At lower air
temperatures the process can
be started and operated for a
while (approx. 15 min.) where-
after the system can be
pressurised.
Correct the error indicated by the
function LED's, see page 21 - 22.
Check that the wiring is correct.
Closing 1 + 9 or 10 shall start
the filter.
There is an electrical fault in one
or more of the pilot valves. The
number/s shown after Err are the
number of the faulty valve/s.
Depressurise the system. Check
that the leads to the valve coil are
properly connected. Remove the
leads and measure the resistance
of the coil, it shall be approxi-
mately 26 Ω . If the resistance is
more than 29 Ω or less than 23 Ω
or if the coil circuit is cut, replace
the pilot valve.
26
Need help?
Do you have a question about the FilterMax F Series and is the answer not in the manual?