Charging Container In Air Conditioner Service Station With Refrigerant; Draining Air Conditioner Service Station - Volkswagen Amarok 2011 Workshop Manual

Hide thumbs Also See for Amarok 2011:
Table of Contents

Advertisement

Amarok 2011 ➤ , Beetle 2012 ➤ , Bora 1999 ➤ , CC 2010 ➤ , CC 2012 ➤ , ...
– Start with engine with air conditioner compressor switched off
(if it is the type with a magnetic clutch).
– Set air conditioner compressor to lowest possible setting; se‐
lect "ECON" mode or "A/C Off" (if version without magnetic
clutch, but with regulating valve).
– Wait until idling speed has stabilised.
– Switch air conditioner compressor on and let system run for at
least 2 minutes with engine idling.
– If necessary, check pressures in refrigerant circuit using air
conditioner service station.
– Switch off engine.
– Turn out handwheel on quick-release coupling adapter.
– Detach the charging hose from the refrigerant circuit.
– Screw on sealing caps again.
5.7
Charging container in air conditioner
service station with refrigerant
Always follow the procedure described in the user's manual
for your air conditioner service station.
For every air conditioning system, a certain amount of refrig‐
erant is prescribed as the required charge To ensure that the
system is neither overcharged nor undercharged with refrig‐
erant (both circumstances will impair the function of the air
conditioning system), the refrigerant container is on a weigh‐
ing machine.
5.8

Draining air conditioner service station

Note
If it becomes necessary to drain the air conditioner service
station (e.g. because contaminated refrigerant was extracted),
all filters and dryers are to be renewed as a rule. Do not take
the filters and dryers out of their airtight packaging until im‐
mediately prior to installation in order to keep moisture ab‐
sorption (hygroscopic property) as low as possible.
Refrigerant bottles that have been charged with contaminated,
used refrigerant are referred to as "recycling bottles".
Recycling bottles must be evacuated as a rule before being
filled for the first time with refrigerant. Refrigerant bottles that
have air in them must not be filled with refrigerant.
Different types of refrigerants must not be mixed with each
other. Mixed refrigerants cannot be processed for reuse. They
have to be disposed of. If the composition of the contents of
the bottle is uncertain, the refrigerant recycler must be in‐
formed of this.
Air conditioning system with refrigerant R134a - Edition 10.2014