Amarok 2011 ➤ , Beetle 2012 ➤ , Bora 1999 ➤ , CC 2010 ➤ , CC 2012 ➤ , ...
Air conditioning system with refrigerant R134a - Edition 10.2014
Possible deviation
from specification
•
High pressure nor‐
mal or too high,
•
Low pressure too
high (see dia‐
gram),
•
The air conditioner
compressor is
noisy (especially
immediately after
being switched
on),
•
The required cool‐
ing output is not
delivered.
Possible deviation from specification
•
High-pressure and low-pressure
are normal,
•
The required cooling output is not
delivered.
•
High-pressure and low-pressure
are normal,
•
The air conditioner compressor is
noisy (especially immediately af‐
ter being switched on),
•
The cooling power required is de‐
livered.
134
Rep. gr.00 - Technical data
Possible cause of fault
Too much refrigerant in
circuit.
Too much refrigerant oil in circuit.
Rectifying
fault
– Extract
some re‐
frigerant
from the
refriger‐
ant cir‐
cuit.
•
The
quantity
of refrig‐
erant ex‐
tracted is
about
equal to
the pre‐
scribed
charge
quantity.
– Renew
the air
condition‐
er com‐
pressor.
•
The
quantity
of refrig‐
erant ex‐
tracted is
signifi‐
cantly
greater
than the
prescri‐
bed
charge
quantity.
– Recharge
refriger‐
ant cir‐
cuit.
– Repeat
check.
Possible cause of fault
Rectifying fault
– Drain refrigerant cir‐
cuit.
– Purge (clean) refrig‐
erant circuit
⇒ page 67
.