Dc Power Supply Specifications - Avaya 8400 Manual

Installation job aid for virtual services platform
Hide thumbs Also See for 8400:
Table of Contents

Advertisement

Table 6: DC power supply LED states
Color and Status
Off
Green (steady)
Green (blinking)
Amber (steady)
Amber (blinking)
Important:
You can hot swap power supplies while the switch is operational. One power supply is
required for continued switch operation.

DC power supply specifications

The VSP 8404–DC comes with one 800 W DC power supply and you can install a secondary power
supply for redundancy.
Important:
You must have either a power supply or a power supply cover in each bay to ensure proper
ventilation. Leaving a power supply bay unpopulated or uncovered impairs the ability of the fans
to cool the chassis.
Figure 3: DC power supply
The 800 W DC power supply uses a DC power supply wiring assembly to connect the power supply
to the DC power source.
June 2015
Description
There is no DC power to either power supply.
There is output and the power supply is
operating normally.
The power supply is present, but its output is
standby voltage (12VSB).
SHUTDOWN: The power supply is not supplying
power to the switch because the power cord is
unplugged or the power supply shutdown for
faults such as a fan failure or exceeding limits for
Over Current Protection (OCP) or Over Voltage
Protection (OVP).
WARNING: The power supply continues to
operate, but there are one or more warning
events such as high temp, high power, high
current, or a slow fan.
Installation Job Aid for Avaya Virtual Services Platform 8400
12

Advertisement

Table of Contents
loading