Ac Power Cord Specifications - Avaya 8400 Manual

Installation job aid for virtual services platform
Hide thumbs Also See for 8400:
Table of Contents

Advertisement

Figure 2: IEC 60320 C16 connector
The following table describes the regulatory AC power specifications for the VSP 8404 switch. Note
that regulatory power specifications are based on the maximum rated capacity of the power supplies
and are not based on typical power consumption, which is typically lower.
Table 4: AC power specifications
Input Current:
Input Voltage (rms):
Power Consumption:
Thermal Rating:
Inrush Current:
Turn on Condition:
Important:
12 V output rise time, from 10 to 90 percent, must be the maximum of 50 ms and monotonic under all
defined input and output conditions.
Efficiency:

AC power cord specifications

To connect AC power to the switch, you need an appropriate AC power cord as described in the
following table, also see the following table for plug specifications.
Table 5: International power cord specifications
Country and Plug Specification
Continental Europe:
• CEE7 standard VII male plug
• Harmonized cord (HAR marking on the outside of the cord
jacket to comply with the CENELEC Harmonized
Document HD-21)
United States of America, Canada, and Japan:
• NEMA5-15P male plug
• UL-recognized (UL stamped on cord jacket)
June 2015
VSP 8404–AC
9.9–4.79 A
100–240 V, 47–63 Hz
800 W maximum
2730 BTU/Hr maximum
40 A maximum
1 second maximum after application of AC power
70 percent minimum
Specifications
• 220 or 230VAC
• 50 Hz
• Single phase
• 100 or 120VAC
• 50–60 Hz
• Single phase
Installation Job Aid for Avaya Virtual Services Platform 8400