Hardware Installation; First Thing To Do: Interface Settings - Moxa Technologies Industio CI-134 Series User Manual

Industrial 4 port rs-422/rs-485 serial board
Hide thumbs Also See for Industio CI-134 Series:
Table of Contents

Advertisement

The installation of the Industio CI-134 Series consists of hardware and software
installation. The hardware installation is detailed in this chapter. The next chapter
deals with the software installation for various operating systems.

First Thing to Do: Interface Settings

1. Before installing the board into the slot, you should set all the jumpers and
2
CAP Jumper
Interface Switch
Data Mode Switch
ON
ON
ON
JP1
1 2 3
4
1 2 3 4
Industio CI-134 Series Board
switches to what you want. The default (factor y) settings ar e set to RS-485,
Auto Data Dir ection Contr ol mode, indicated as *.
l
CAP Jumper JP1:
Open * Not forcing the CAP address to 0xA700.
Shor t
Force the CAP address to 0xA700. Set to this if you want to do
quick har dwar e installation. Or forget the CAP address when
you want to re-configure the board with IO-IRQ.

Hardware Installation

Termination Resistor Jumper for Port 1
Termination Resistor Jumper for Port 2
Termination Resistor Jumper for Port 4
Termination Resistor Jumper for Port 3
JP5
JP6
JP4
JP3
Industio CI-134 Series User' s Manual
2
2
2-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Industio ci-134iIndustio ci-134Industio ci-134is

Table of Contents