Gas And Electrical Access Panels; Gas Line Specifications & Access - Heat&Glo FOUNDATION Series Installation And Operating Manual

Single sided co-linear direct vent gas fireplaces
Hide thumbs Also See for FOUNDATION Series:
Table of Contents

Advertisement

B. GAS AND ELECTRICAL ACCESS PANELS
Each fireplace will have four points of access for installation and service. There are access panels on the pilot side of the fireplace front, side and rear
of the fireplace. Plan in advance of the installation which access location will be used and accommodate for it in the finish work to allow for
easy access to service later. You also have access through the interior of the fireplace by removing the mesh on the burner pan in the pilot area.
There are gas and electrical gas knock-outs on the bottom if you need to come up from below the fireplace.
SIDE ACCESS PANEL
ELECTRICAL ACCESS
GAS ACCESS
3 [76]
1 25/32 [45]
2 7/32 [56]
5 13/32 [137]
GAS AND ELECTRICAL KNOCK-OUTS
5-7/16 [138]
2X 2-15/16 [75]
2X 7-15/32 [190]
2X 8-23/32 [222]
ELECTRICAL ACCESS
Figure 7.B Access Panel Dimensions
Heat & Glo • FDN-4-SS, FDN-5-SS, FDN-6-SS, FDN-7-SS Installation Manual • 16400-9800 Rev. H • 11/19
7 - GAS LINE SPECIFICATIONS & ACCESS
MEASUREMENTS = INCHES [mm]
(PILOT SIDE)
See Valve and Electrical Access in the
Maintenance Section for details on
access through the burner.
ELECTRICAL ACCESS
GAS ACCESS
2X 2 27/32 [41]
2X 1 19/32 [41]
2 7/32 [56]
BOTTOM VIEW
5-13/32 [137]
2X 2-29/32 [74]
2X 3-31/32 [101]
6X
7/8 [22]
6X
1-3/32 [28]
FRONT ACCESS PANEL VIEW
3 [76]
1-1/2 [38]
1-11/16 [43]
2-3/4 [70]
3-27/32 [98]
2X 11-3/4 [857]
BACK ACCESS PANEL VIEW
GLASS
BACK WALL
ELECTRICAL ACCESS
GAS ACCESS
1-11/16 [43]
1-1/2 [38]
3-27/32 [98]
2-3/4 [70]
2X 11-3/4 [299]
3 [76]
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fdn-4-ssFdn-5-ssFdn-6-ssFdn-7-ss