Capacity extension

Advertisement

Quick Links

Server
PRIMERGY S40-DF
Capacity Extension
Xenia Fierley
Siemens Nixdorf Informationssysteme AG ICP CS PS QM 3
81730 München
e-mail: email: manuals@fujitsu-siemens.com
Tel.: (089) 636-47896
Fax: 0 700 / 372 00000
U41100-J-Z156-1-74
Sprachen: En
Edition May 2001

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu PRIMERGY S40-DF

  • Page 1 Server PRIMERGY S40-DF Capacity Extension Xenia Fierley Siemens Nixdorf Informationssysteme AG ICP CS PS QM 3 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 636-47896 Fax: 0 700 / 372 00000 U41100-J-Z156-1-74 Sprachen: En Edition May 2001...
  • Page 2: Copyright And Trademarks

    There you will also find the addresses of the relevant User Documentation Department Copyright and Trademarks Copyright © 2001 Fujitsu Siemens Computers GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.
  • Page 3 German English...
  • Page 5: Table Of Contents

    Contents PRIMERGY S40-DF capacity extension ... . . 1 Target group ......2 Notational conventions .
  • Page 7: Primergy S40-Df Capacity Extension

    PRIMERGY S40-DF capacity extension The PRIMERGY S40-DF is the active component in the PRIMERGY S40 family of storage subsystems. The integrated disk array controller allows you to extend storage capacity using additional externally-connected passive PRIMERGY S40-ES storage devices. Two of these so-called “daisy-chain” configurations, i.e., with one or three PRIMERGY S40-ES units, are supported (see also the...
  • Page 8: Target Group

    Target group PRIMERGY S40-DF capacity extension Target group These conversion instructions are intended for those who are responsible for installing hardware and for ensuring that the system runs smoothly (service personnel, technicians and technical specialists). You will therefore need to be familiar with the hardware and data transmission concepts to understand the various activities described.
  • Page 9: Important Notes

    1.3.1 Notes on safety Please observe all the safety instructions given in the documentation of the PRIMERGY S40-DF as well as the following notes: CAUTION! The actions described here should only be performed by technicians, service personnel or technical specialists. Any failure to observe the guidelines in this manual could expose the user to considerable risks (electric shock, fire hazards) and could also damage the equipment.
  • Page 10: Notes On Transportation

    Important notes PRIMERGY S40-DF capacity extension When handling ESD-sensitive devices, it is essential that you observe the following guidelines: Ê You must electrostatically discharge yourself (e.g. by touching a grounded object) before handling such components. Ê Any devices or tools that are used must be free from electrostatic charge.
  • Page 11: Converting The Primergy S40-Df

    PRIMERGY S40-DF capacity extension Converting the PRIMERGY S40-DF Converting the PRIMERGY S40-DF In order to install expanded storage capacity using one or three PRIMERGY S40-ES storage subsystems, you will need the corresponding conversion kit. This conversion kit contains the following components: –...
  • Page 12 Note that if the PRIMERGY S40-ES is connected, the system parameters PWR ON/OFF BY BUTTON and PWR ON/OFF BY CAN must be set to DISABLE. Ê Connect the PRIMERGY S40-DF and the three PRIMERGY S40-ES units to the power supply. Ê Connect the PRIMERGY S40-DF to the PRIMERGY server.
  • Page 13 Note that if the PRIMERGY S40-ES is connected, the system parameters PWR ON/OFF BY BUTTON and PWR ON/OFF BY CAN must be set to DISABLE. Ê Connect the PRIMERGY S40-DF and the three PRIMERGY S40-ES units to the power supply. Ê Connect the PRIMERGY S40-DF to the PRIMERGY server.
  • Page 14: Removing And Mounting The Door

    Converting the PRIMERGY S40-DF PRIMERGY S40-DF capacity extension 1.4.1 Removing and mounting the door Since the same method applies to both the floorstand and stackable models, only the floorstand model is shown in the following figure. Figure 2: Removing the door (floorstand model) Ê...
  • Page 15: Removing And Mounting The Side Or Top Cover

    PRIMERGY S40-DF capacity extension Converting the PRIMERGY S40-DF 1.4.2 Removing and mounting the side or top cover Figure 3: Removing the side cover (floorstand model) Figure 4: Removing the top cover (stackable model) Ê Press the two buttons (1) and remove the left side cover or the top cover (2).
  • Page 16: Removing And Mounting The Protective Shield

    Converting the PRIMERGY S40-DF PRIMERGY S40-DF capacity extension 1.4.3 Removing and mounting the protective shield Since the same method applies to all housing models, only the rack-mounted model is shown in the following figures. Figure 5: Unlocking the protective shield Ê...
  • Page 17: Converting The Internal Configuration

    In order to install a capacity expansion with three PRIMERGY S40-ES units, you will need to first change the internal cabling of the PRIMERGY S40-DF from a 3-channel configuration (figure 8 on page 12) to a 1-channel configuration (figure 12 on page 16).
  • Page 18 Converting the PRIMERGY S40-DF PRIMERGY S40-DF capacity extension Figure 8: Internal cabling for 3-channel configuration - initial state U41100-J-Z156-1-74...
  • Page 19 PRIMERGY S40-DF capacity extension Converting the PRIMERGY S40-DF Figure 9: Removing the STM-LVD modules Ê Pull out the SCSI addressing cable (1) from the connection ports on the STM-LVD modules of the SCSI drive cages 2 and 3. For cage 1, the STM-LVD module remains connected with the SCSI addressing cable on the backplane.
  • Page 20 Converting the PRIMERGY S40-DF PRIMERGY S40-DF capacity extension Figure 10: Controller backplane: SCSI ports - initial state Ê Pull out the SCSI connection cable for cage 1 (3.1) from the controller backplane (see also figure 8 on page 12) and connect it to the freed SCSI connector X1 (see figure 12 on page 16) on the backplane of cage 2 (see figure 11 on page 15).
  • Page 21 PRIMERGY S40-DF capacity extension Converting the PRIMERGY S40-DF Figure 11: 1-Setting up the channel configuration Ê Connect the supplied OLR/STM-LVD flat ribbon cable as follows: – Connect the common end (4) of the two cable strands with the connector X5 on the STM-LVD module on the backplane of cage 1 (see also figure 12 on page 16).
  • Page 22 Converting the PRIMERGY S40-DF PRIMERGY S40-DF capacity extension Figure 12: Internal cabling for 1-channel configuration - final state U41100-J-Z156-1-74...
  • Page 23: Installing The Lvd Extender Board

    PRIMERGY S40-DF capacity extension Converting the PRIMERGY S40-DF 1.4.5 Installing the LVD extender board The insertion slot for the LVD extender board is on the back of the storage subsystem and is covered by a plate. If you need further assistance, refer to the operating instructions for the “PRIMERGY S40-DF Storage Subsystem“.
  • Page 24 Converting the PRIMERGY S40-DF PRIMERGY S40-DF capacity extension CAUTION! Please observe the notes pertaining to the ESD label in the section “Important notes” on page 3. Figure 14: Installing the LVD extender board CAUTION! Before installing the board, make sure that all DIP switches are set to ON.
  • Page 25: Connecting The Capacity Extension

    PRIMERGY S40-DF capacity extension Converting the PRIMERGY S40-DF 1.4.6 Connecting the capacity extension PRIMERGY S40-DF 1 channel version LVD extender PRIMERGY PRIMERGY PRIMERGY S40-ES S40-ES S40-ES 1 channel 1 channel 1 channel version version version Figure 15: PRIMERGY S40-DF with capacity extension Ê...
  • Page 27: Related Publications

    Related publications Please apply to your local office for ordering the manuals. Safety, Guarantee and Ergonomics 19-Inch Rack for PRIMERGY and RM Systems Technical Manual PRIMERGY S40-DF Storage Subsystem Operating Manual PRIMERGY S40-BS/ES Storage Subsystem Operating Manual U41100-J-Z156-1-74...
  • Page 29: Index

    Index capacity expansion 1, 5, 11 configuration converting the internal configu- ration 11 conversion kit 5 ESD label 3 LVD extender board installing 17 mounting/removing the protective shield 10 mounting/removing the side cover 9 notational conventions 2 notes on safety 3 OLR/STM-LVD flat ribbon cable 15 removing/mounting the door 8 SCSI addressing cable 13...
  • Page 31 Comments Fujitsu Siemens Computers GmbH User Documentation 81730 München Suggestions Germany Corrections Fax: 0 700 / 372 00000 email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.com Submitted by Comments on PRIMERGY S40-DF Capacity Extension U41100-J-Z156-1-74...
  • Page 33 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu- ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So- lutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.