Positioning Operating mode
8.3
Starting and Stopping the Axes
Table 8-5
Start/stop block
Address
Name
Start_Stop_Block
+0.0
Start_Axis_1
+0.1
Stop_Axis_1
+0.2
Start_Axis_2
+0.3
Stop_Axis_2
+0.4
Start_Axis_3
+0.5
Stop_Axis_3
+0.6
Start_Axis_4
+0.7
Stop_Axis_4
+1.0
CoordinationByte
=2.0
8-14
The following conditions must be met before an axis is started for the first
time.
The module is parameterized (SF LED is off).
S
The actual value for the axis to be started has been set.
S
A setpoint was written for the axis to be started.
S
To start the axis, write the start/stop block to address
"module start address + 2."
Note
Before an axis can be started again, it must be stopped with a stop command.
Table 8-5 shows the contents of the start/stop block. The required assign-
ment of the coordination byte is entered in the structure as an initial value.
For a description of the bit assignment of the coordination byte, see chapter
4.3.1.
The write- - access of the start/stop block must be programmed as a word- -
access.
Type
STRUCT
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BYTE
END_STRUCT
Initial Value
Commentary
FALSE
01: Start axis 1
10: Stop axis 1
FALSE
FALSE
01: Start axis 2
10: Stop axis 2
FALSE
FALSE
01: Start axis 3
10: Stop axis 3
FALSE
FALSE
01: Start axis 4
10: Stop axis 4
FALSE
B#16#84
Start/stop byte enable = 1
C bit = 0/ positioning mode
(4) J31069-D0416-U001-A5-7618
CM35 Counter Module