Technical Specification - Infinity 780HD Instruction For Users

Table of Contents

Advertisement

Technical Specification

Model
Gas
Gas
CAT
Type
780 HD
I2H
Natural
Gas
Power Supply Type Plug – Input : 100-240 VAC 50/60 Hz, 0.2A
Note : The efficiency of the appliance has been measured as specified in BS7977-1 2009+
A1:2013 and the net efficiency rate is 71.8%. The gross calorific value of the fuel has been used
for this efficiency calculation. Gastec have certified the test data from which it has been
calculated. The efficiency value may be used in the UK Government's Standard Assessment
Procedure (SAP) for energy rating of the dwelling. Within the appliance packaging will be an
outlet restrictor, this is there to achieve the maximum efficiency. This, however may not be fitted
due to the flue underperforming.
P a g e
| 24
780 HD INSTALLATION INSTRUCTIONS
Working
Front
Pressure
Injector
20
Mrk
mbar
220
Efficiency Class 1
Gas Inlet Connection Size 8mm
Handset Replacement Batteries 4 x AAA 1.5V
Rear
Gas
NOX
Injector
Input
Class
Mrk
6.6 KW
290
Gross
Oxy
Country
Pilot
5
2550
GB, IE
NGR
LT7185 Issue No 1 (04/17)