Ipi Electronic System Wiring Diagram - Empire Comfort Systems MILLIVOLT 3 Series Installation Instructions And Owner's Manual

B-vent zero clearance gas fireplace
Table of Contents

Advertisement

IPI ELECTRONIC SYSTEm WIRING dIAGRAm

REMOTE
RECEIVER
(OPTIONAL)
ON
REMOTE
OFF
MANUAL RESET
LIMIT SWITCH
AC/DC
POWER
f i r e - p a r t s . c o m
ADAPTOR
BATTERY
BATTERY
HOLDER
BATTERY
If any of the original wire as supplied with this unit must be
replaced, it must be replaced with equivalent gauge and
temperature rated wire.
This appliance is only for use with the type of gas indicated
on the rating plate and may be installed in an aftermarket,
permanently located, manufactured (mobile) home where not
prohibited by local codes. This appliance is not convertible for
use with other gases, unless a certified kit is used.
do not operate the appliance with panel(s) removed,
cracked or broken. Replacement of the panel(s) should be
done by a licensed or qualified service person.
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury
or loss of life. Installation and service must be performed
by a qualified installer, service agency or the gas supplier.
Page 24
WALL
ON/OFF
OR
SWITCH
SWITCH
WHITE
GREEN
BLACK
RED
BLACK
RED
CAUTION
WARNING
BLUE
BLUE
WHITE
WHITE
CPI/IPI
SWITCH
GREEN
ORANGE
YELLOW
GAS CONTROL VALVE
GROUND
Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding)
plug for your protection against shock hazard and should
be plugged directly into a properly grounded three-prong
receptacle. do not cut or remove the grounding prong from
this plug. The AC/dC adapter, if used, has a 2-prong plug
which does not require an additional ground.
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation.
PILOT
ORANGE
ELECTRONIC
CONTROL MODULE
WARNING
CAUTION
38142-2-0719