Ipi Electronic System Wiring Diagram - Empire Comfort Systems INTERMITTENT PILOT DVCD36FP70 Installation Instructions Manual

Direct vent zero clearance gas fireplace
Table of Contents

Advertisement

ipi electronic sYstem Wiring diagram

CPI/IPI
SWITCH
REMOTE RECEIVER
(OPTIONAL)
+ ON
REMOTE
- OFF
AC/DC
POWER ADAPTOR
BATTERY
BACK-UP
BATTERY HOLDER
If any of the original wire supplied with this fireplace must
be replaced, it must be replaced with equivalent gauge and
temperature rated wire.
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Page 74
ON/OFF
OR
SWITCH
caUtion
GAS CONTROL
VALVE
(GND)
figure 80
PILOT
ELECTRONIC
CONTROL MODULE
38712-2-0719