INTERmITTENT PILOT PROPANE GAS CONVERSION

The conversion shall be carried out in accordance with the
requirements of the provincial authorities having jurisdiction
and in accordance with the requirements of the CSA B149.2
installation code (Canada) and with the requirements of the
National Fuel Gas Code Z223.1/NFPA 54 (United States).
WARNING: This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer's
instructions and all applicable codes and requirements of
the authority having jurisdiction. If the information in this
instruction is not followed exactly, a fire, explosion, or
production of carbon monoxide may result causing property
damage, personal injury, or loss of life. The qualified service
agency is responsible for the proper installation of this kit.
The installation is not proper and complete until the operation
of the converted appliance is checked as specified in the
manufacturer's instructions supplied with the kit.
SAFETY SHUTdOWN SYSTEm
Intermittent Pilot System
1.
Switch main switch to "OFF" position. Main burner and pilot should go off.
2.
Pilot gas flow should stop within 30 seconds.
3.
Relight pilot burner and operate system through one complete cycle to make sure all controls operate properly.
f i r e - p a r t s . c o m
Part description
Fireplace
Pilot Orifice
Main Burner Orifice
Regulator Kit, Sit
Gas Conversion Label
Gas input for "B-Vent" fireplace converted to Propane Gas
BVd34FP3 SERIES
BVd36FP3 SERIES
BVP42FP3 SERIES
The "B-Vent" fireplace when converted to Propane Gas will have
manifold pressure of 10.0" w.c. at the valve outlet with the inlet
pressure to the valve from a minimum of 10.8" w.c., for the purpose
of input adjustment, to a maximum of 14.0" w.c.
38142-2-0719
"Kit No. 38146"
"BVD34FP 7 Series"
"BVD36FP 7 Series"
"#35 R-7658"
"1.35 mm P-289"
R-12582
2139
21,000 BTU per hour
25,000 BTU per hour
30,000 BTU per hour
Installer notice: Using an ink pen, fill out the required information
on the conversion label. Remove the backing from label and stick
label in a visible position on bottom of fireplace close to gas valve.
Installer notice: These instructions must be left with the appliance.
Instructions for converting your direct ignition fireplace from
Natural Gas to Propane Gas.
All Intermittent Pilot fireplaces are shipped from the factory equipped
to operate on Natural Gas. To convert the direct ignition fireplace
to operate on Propane Gas, follow the instructions below. Please
see the appropriate parts list for your model for parts included with
the Intermittent Pilot fireplace.
Check the items in the kit with the parts list. Notify the supplier of
any items that are missing before installing the conversion kit.
PARTS LIST
"Kit No. 38147"
"BVP42FP 7 Series"
"#35 R-7658"
"1.45 mm P-209"
"1.65 mm P-250"
R-12582
2139
INSTRUCTIONS FOR CONVERSION
1.
If the fireplace is installed, turn off gas and electric supply before
making the gas conversion.
2.
Identify the fireplace model to be converted, and read all
instruction steps prior to converting the gas valve.
3.
Remove all logs from the burner assembly.
4.
Open the sliding valve access door.
5.
Depress and turn the gas shut-off dial to the "OFF" position.
VALVE CONVERSION
6.
Remove two (2) screws, regulator, and gasket from gas valve
control body.
7.
Install the new gasket, regulator, and gasket from gas valve
control body.
"Kit No. 38148"
quantity Supplied
"#35 R-7658"
R-12582
2139
1
1
1
1