jUNCTION BOX WIRING INSTALLATION INSTRUCTIONS

All wiring should be done by a qualified electrician and shall be in compliance with all local,
city and state building codes. Before making the electrical connection, make sure that main
power supply is disconnected. The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes, with the national electrical code ansi/
nfpa 70 (latest edition).
A factory installed junction box is located on the lower right
side of the fireplace. Wiring must be fed to the junction
box and attached to the receptacle that is provided. Leave
approximately 6" of wire in the junction box for connection.
f i r e - p a r t s . c o m
Page 40
STANdARd mILLIVOLT VALVE mOdELS
CAUTION
Attach black wire to one side of the receptacle and white
wire to opposite side of receptacle. The ground wire should
be attached to the green (ground) screw.
Install the receptacle into the junction box. Attach cover plate.
Figure 28
38142-2-0719