ZKTeco ProFace X Quick Start Manual
Hide thumbs Also See for ProFace X:

Advertisement

Quick Start Guide
ProFace X
Version: 1.0
Date: May 2019

Advertisement

Table of Contents
loading

Summary of Contents for ZKTeco ProFace X

  • Page 1 Quick Start Guide ProFace X Version: 1.0 Date: May 2019...
  • Page 2 1Overview Flash Near-infrared flash Camera Microphone 8-inch touchscreen Tamper switch Speaker Reset button +12V Power RS232 RXD1 Power Auxiliary TXD1 interface input 485B RS485 485A Sensor Exit button Wiegand Lock INWD1 Wiegand INWD0 Alarm Networkinterface...
  • Page 3: Device Installation

    2 Device Installation Install on the wall ①Attach the mounting template sticker to the wall, and drill holes according to the mounting paper. ②Fix the back plate on the wall using wall mounting screws. ③Attach the device to the back plate. ④Fasten the device to the back plate with a security screw.
  • Page 4 2Device Installation Install on the barrier gate Please thread the wire through the bracket before installation. ①Drill a hole on the barrier gate, insert the bracket into the hole and fix it with a nut. ②Adjust the angle of the device. ①...
  • Page 5: Standalone Installation

    3Standalone Installation Smoke Alarm detector Door sensor Exit button Reader Lock TCP/IP 4Door Sensor, Exit Button & Alarm Connection Detector power Smokedetector Door sensor Exitbutton Alarm Alarm power...
  • Page 6 5Lock Relay Connection The system supports Normally Opened Lock and Normally Closed Lock. The NO LOCK (normally unlocked when power-on) is connected with 'NO' and 'COM' terminals, and the NC LOCK (normally locked when power-on) is connected with 'NC' and 'COM' terminals. Take NC Lock as an example below: 1)Device not sharing power with the lock 2)Device sharing power with the lock...
  • Page 7 7 Barrier Connection RXD1 TXD1 485B Barrier gate 485A 8RS485Connection +12V RXD1 TXD1 485- 485B 485+ 485A 485 reader Note: 485A and 485B can be connected to the barrier gate or the 485 reader, but cannot be connected to the gate and the reader at the same time.
  • Page 8: Power Connection

    9Power Connection 12V3ADC Recommended power supply: 12V - 3A To share the power with other devices, use a power supply with higher current ratings. 10Ethernet Connection Connect the device and computer software over an Ethernet cable. An example is shown below: Default IP address : 192.168.1.201 IP address...
  • Page 9: User Registration

    11 UserRegistration When there is no super administrator set in the device, click on to enter the menu. After setting the super administrator, the system will request for the administrator’s verification before entering the menu. For the security purpose, it is recommended to register a super administrator at the first time you use the device.
  • Page 10: AccessControlSettings

    12AccessControlSettings to enter the access control management interface and set relevant Clickon > [Access Control] parameters of access control. 13Ethernet and Cloud Server Settings Clickon > [Comm.] > [Ethernet]to set the network parameters. If the TCP/IP communication of the device is successful, the icon will be displayed in the upper right corner of the standby interface.
  • Page 11 ZKBuildingWuhe Road, Gangtou, Bantian, Buji Town, Longgang District, Shenzhen China 518129 Tel:+86 755-89602345 Fax:+86 755-89602394 www.zkteco.com Copyright©2019 ZKTeco CO., LTD. All rights reserved.