Summary of Contents for ZKTeco SF1008+

  • Page 1 Quick Start Guide SF1008+ Version: 1.0 Date: April 2020...
  • Page 2 1Overview Flash Thermal infrared temperature measurement module Near-infrared flash Camera & palm collector Microphone (Optional) 8-inch touchscreen Tamper switch Speaker Reset button +12V Power RS232 RXD1 Power Auxiliary TXD1 interface input 485B RS485 485A Sensor Exit button Wiegand Lock INWD1 Wiegand INWD0 Alarm...
  • Page 3: Installation Environment

    2 Installation Environment Please refer to the following recommendations for installation. 10ft INDOOR USE KEEP DISTANCE AVOID GLASS AVOID DIRECT KEEP EFFECTIVE REFRACTION SUNLIGHT DISTANCE AND EXPOSURE 20-50cm 3 Device Installation Install on the wall ①Attach the mounting template sticker to the wall, and drill holes according to the mounting paper. ②Fix the back plate on the wall using wall mounting screws.
  • Page 4 3 Device Installation Install on the barrier gate Please thread the wire through the bracket before installation. ①Drill a hole on the barrier gate, insert the bracket into the hole and fix it with a nut. ②Adjust the angle of the device. ①...
  • Page 5: Standalone Installation

    4 Standalone Installation Smoke Alarm detector Door sensor Exit button Reader Lock TCP/IP 5 Door Sensor, Exit Button & Alarm Connection Detector power Smokedetector Door sensor Exitbutton Alarm Alarm power...
  • Page 6 6 Lock Relay Connection The system supports Normally Opened Lock and Normally Closed Lock. The NO LOCK (normally unlocked when power-on) is connected with 'NO' and 'COM' terminals, and the NC LOCK (normally locked when power-on) is connected with 'NC' and 'COM' terminals. Take NC Lock as an example below: 1)Device not sharing power with the lock 2)Device sharing power with the lock...
  • Page 7 8 Barrier Connection RXD1 TXD1 485B Barrier gate 485A 9 RS485 Connection +12V RXD1 TXD1 485- 485B 485+ 485A 485 reader Note: 485A and 485B can be connected to the barrier gate or the 485 reader, but cannot be connected to the gate and the reader at the same time.
  • Page 8: Power Connection

    10 Power Connection 12V3ADC Recommended power supply: 12V - 3A To share the power with other devices, use a power supply with higher current ratings. 11 Ethernet Connection Connect the device and computer software over an Ethernet cable. An example is shown below: ZKBioAccessEP Default IP address : 192.168.1.201...
  • Page 9: User Registration

    12 UserRegistration When there is no super administrator set in the device, click on to enter the menu. After setting the super administrator, the system will request for the administrator’s verification before entering the menu. For the security purpose, it is recommended to register a super administrator at the first time you use the device.
  • Page 10 Method 2: Register on ZKBioAccess EP software Please set the IP address and cloud service server address on the device. 1. Click [Access] > [Access Device] > [Device] > [Search Device] to add the device to the software. When the device has set the server address and port, it can be added automatically. Step1 Step2 Step3...
  • Page 11 Method 3: Register on the phone Once ZKBioAccess EP software installed, users could enroll face via browser application on their own mobile phone. 1. Click [Personnel] > [Parameters], input ‘’http://Server address:Port’’ in the QR Code UGL bar. The software will automatically generates a QR code. Scan the QR code or login onto ‘’http://Server address:Port/app/v1/adreg’’...
  • Page 12: Access Control Settings

    13 Access Control Settings to enter the access control management interface and set relevant Clickon > [Access Control] parameters of access control. 14 Ethernet and Cloud Server Settings Clickon > [Comm.] > [Ethernet]to set the network parameters. If the TCP/IP communication of the device is successful, the icon will be displayed in the upper right corner of the standby interface.
  • Page 13 15 Detection Management Settings Click on > [System] > [Detection Management]to enter the detection management interface . You can set the value of High temperature alarm threshold. The device will send an alarm prompt when the temperature of the user detected exceeds this value. When the Temperature over the range; access denied is enabled, the user will be forbidden to access, as shown in the following figure.
  • Page 14 Note: 1. The effective distance for temperature detection is within 50cm. 2. Recommended for indoor use. 3. Temperature measurement data is for reference only, not for medical use. 4. Remove the mask to register the face, wear a mask to recognize the face, the type of mask, the size of the face covered by the mask, and bangs will affect the facial recognition effect.
  • Page 15 For more details, please refer to the ZKBioAccess EP User Manual.
  • Page 16 16 Method for Enrolling Palm Note: 1. Place your palm within 20-50cm of the device. 2. Place your palm in the palm collection area, such that the palm is placed parallel to the device. 3. Make sure to keep space between your fingers.
  • Page 17 1600 Union Hill Road Alpharetta, GA 30005 Phone: (861) 505 2101 www.zktecousa.com Copyright©2020 ZKTeco USA LLC. All rights reserved.