12.5 F117

The red LED is flashing.
The buzzer and the alarm symbol are on.
Display text: F117.
Cause
The cable between the main board and the display is not con-
nected properly.
The cable between the main board and the display is not con-
nected properly or is defective.
The problem is still not solved.
The connectors between the main board and the display may
be defective.

12.6 RELAY

The red LED is flashing.
The buzzer and the alarm symbol are on.
Display text: RELAY.
The pump does not start or stop.
The symbol of the pump is flashing.
Find the cause of the alarm by means of the fault code in the information menu F_01.
Fault
Cause
code
F015
The relay or contactor for pump 1 is defective. The pump does not stop.
F017
The relay or contactor for pump 2 is defective. The pump does not stop.
F016
The relay or contactor for pump 1 does not close. The pump does not start.
The motor-protective circuit breaker has tripped, or the main board is de-
fective.
F018
The relay or contactor for pump 2 does not close. The pump does not start.
The motor-protective circuit breaker has tripped, or the main board is de-
fective.
Solution 1
1. Switch off the power supply to stop the pump.
2. Replace the defective relay or contactor.
Solution 2
1. Reset the motor-protective circuit breaker.
2. Start the pump manually and make sure that it is running.
3. If resetting the motor-protective circuit breaker does not solve the problem, contact the near-
est Grundfos sales company.
Multilift MD1, MDV | Fault finding the product| 40
Remedy
Disconnect and reconnect the
cable.
Replace the cable.
Use an ethernet cable, RJ45.
Contact the nearest Grundfos
sales company.
Remedy
Solution 1