Multilift MD1, MDV | Table of contents | 2 Original installation and operating instructions Table of contents 1. General information ............4 1.1 Symbols used in this document.
Page 3
Multilift MD1, MDV | Table of contents | 3 7. Control functions ............30 7.1 Settings menu .
Multilift MD1, MDV | General information | 4 1. General information Read this document before you install the product. Installation and operation must comply with local regulations and accepted codes of good practice.
Multilift MD1, MDV | General information | 5 1.1 Symbols used in this document DANGER Indicates a hazardous situation which, if not avoided, will result in death or seri- ous personal injury. WARNING Indicates a hazardous situation which, if not avoided, could result in death or se- rious personal injury.
Multilift MD1, MDV | | 6 2. Receiving the product 2.1 Transporting the product Do not stack the product. WARNING Falling objects Death or serious personal injury ● Secure the product during transportation to prevent it from tilting or falling down.
Multilift MD1, MDV | | 7 2.2 Scope of delivery This list applies to a standard lifting station with one tank. Additional components are included if you have ordered an additional tank. Pos. Quantity Description Specification Pressure tube With 10 m hose...
Multilift MD1, MDV | | 8 3. Installing the product 3.1 Installing the controller 3.1.1 Location Install the product in a location that meets the following requirements: • Place the product in a flood-safe place. • Make sure that the ambient temperature is within the limits.
Multilift MD1, MDV | | 9 3.1.3.1 Connecting the mains supply to systems with direct-on-line starting • Make sure that the supply voltage and frequency correspond to the values stated on the nameplate on the lifting station. • If required according to local regulations, install an external all-pole main switch.
Multilift MD1, MDV | | 10 3.2.2 Mechanical installation CAUTION Back injury Minor or moderate personal injury ● Use lifting equipment. CAUTION Crushing of feet Minor or moderate personal injury ● Wear safety shoes when moving the product. 3.2.2.1 Installing the pumps The description below is for a system with isolating valves and a non-return valve.
Multilift MD1, MDV | | 12 2. Fit the DN 150 socket seal in the inlet port or the optional DN 160 socket if the bottom inlet is chosen. 3. Insert the inlet pipe into the socket seal. To facilitate maintenance and service of the product, we recommend that you fit an isolating valve between the inlet port and the inlet pipe.
Multilift MD1, MDV | | 13 Make sure that the weight from the inlet, outlet and vent pipes does not rest on the tank. Long pipe sections and valves must be supported. 1. Cut off the blanked-off end of the vent port on top of the tank.
Multilift MD1, MDV | | 14 It is necessary to drill the outlet as it may have been filled with tank material during the moulding process. 2. Connect the outlet to the pipe for the diaphragm pump by means of the flexible connecting piece and hose clamps.
Multilift MD1, MDV | Starting up the product| 15 4. Starting up the product 1. Set the selector switches to OFF. 2. Switch on the power supply. It takes up to 45 seconds to boot the controller. 3. When the display is active, select the tank inlet height.
Multilift MD1, MDV | | 16 5. Product description 5.1 Applications The product is designed for the collection and pumping of wastewater with no free flow to sewer level. Typically the product is installed below sewer level in cellars or basements in buildings such •...
Multilift MD1, MDV | | 17 5.3.2 Pumps The pumps are standard wastewater pumps with supporting feet for horizontal installation. The pumps come in two versions: Multilift system Pump version SE1, SL1 pump with single-channel impeller SEV, SLV pump with SuperVortex impeller 5.3.3 Operating modes...
Multilift MD1, MDV | | 18 5.3.5 Level sensor The level sensor consists of a piezoresistive pressure sensor and a pressure tube connected by a pressure hose. The pressure tube is located underneath the screw cap and extends down into the tank.
Multilift MD1, MDV | | 19 5.3.6 Inspection cover The inspection cover enables inspection of the tank during operation. Pos. Description Inspection cover 5.3.7 Non-return valve Lifting stations must be provided with an approved non-return valve according to EN 12050-1 and must be approved according to EN 12050-4.
Multilift MD1, MDV | | 20 5.4 Controller 5.4.1 Display Pos. Description Automatic mode The symbol is on when the selector switch is in position AUTO. Settings locked You can prevent unauthorised persons from making changes to the settings by locking the controller. To unlock the controller, enter this code: 1234.
Multilift MD1, MDV | | 21 Pos. Description High-level alarm The symbol is on if the liquid level has reached the maximum level. Liquid level When the symbol is on, the display shows the liquid level. Values in the form of digits The value of the function selected.
Multilift MD1, MDV | | 22 5.4.3 Selector switches Pos. Description Selector switch, pump 1 Selector switch, pump 2 Set the selector switch to this position to start the pumps man- ually. Set the selector switch to this position to stop the pumps and switch off the power supply to the pumps.
Multilift MD1, MDV | | 23 5.4.5 Menus There are two menus in the controller: • settings menu • information menu Settings menu Menu Designation Description L_01 Start level Set the start level in this menu. I_02 Rated current Set the rated current.
Multilift MD1, MDV | | 26 6. Identification 6.1 Lifting station 6.1.1 Nameplate The nameplate is located on the tank. DK - 8850 Bjerringbro, Denmark Prod.-Nr. P. c. Serial no. m /h Phases 0197 98127055 Made in Germany Pos. Description...
Multilift MD1, MDV | | 27 6.1.2 Type key Example: MD1.80.100.15.4.50D/450-2 SE Code Designation Explanation Type range Multilift lifting station Number of pumps Two pumps Impeller type Single-channel impeller SuperVortex impeller Free passage [mm] Maximum solids size Pump outlet [mm]...
Multilift MD1, MDV | | 28 6.2 Controller 6.2.1 Nameplate The nameplate is located on the side of the control cabinet. DK-8850 BJERRINGBRO DENMARK Type Prod.-No. P.c. Serial no. Phases Pump max Contact max Contact max Fuse max Amb min Amb max Ic <...
Multilift MD1, MDV | | 29 6.2.2 Type key Example: LC 221.2.230.1.10.30 SD Code Designation Explanation LC 221 Controller type Level controller Number of pumps One pump Two pumps Voltage [V] Number of phases Single-phase Three-phase Maximum operating current [A] 30/150 Capacitor size, operation and start, [µF] -...
Multilift MD1, MDV | | 30 7. Control functions 7.1 Settings menu 7.1.1 Start and stop levels The start level of the first pump is preset according to the selected inlet height. The second pump has a higher start level which is activated if the first pump cannot discharge the inflow.
Multilift MD1, MDV | | 31 7.2.3 Impulse counter The impulse counter shows the number of starts for each pump. See the impulse counter in the information menu R_02. 7.2.4 Highest measured motor current The menu shows the highest measured current to each motor.
Multilift MD1, MDV | | 32 8. Operating the product 8.1 Setting the controller 8.1.1 Setting the start level When you switch on the controller for the first time, the startup wizard guides you through the nec- essary settings. If you later want to change the start level, follow these steps: 1.
Multilift MD1, MDV | | 33 8.1.6 Setting the maintenance interval 1. Go to the settings menu. 2. Press OK. 3. Go to menu M_01. 4. Press OK. 5. Press arrow right or left to select the interval: • 0 months •...
Multilift MD1, MDV | Servicing the product| 34 9. Servicing the product DANGER Electric shock Death or serious personal injury ● Switch off the power supply before you start any work on the product. Make sure that the power supply cannot be accidentally switched on.
Multilift MD1, MDV | Servicing the product| 35 9.2.2 Cleaning the pressure tube and hose 1. Set the selector switches to OFF. 2. Close all inlet valves. 3. Loosen the screw cap. 4. Pull the pressure tube carefully out of the tank.
Multilift MD1, MDV | Returning the product for service| 36 10. Returning the product for service 1. If the product cannot be serviced on site, send it to Grundfos or an authorised service work- shop. Costs of returning the product for service are to be paid by the customer.
Multilift MD1, MDV | Taking the product out of operation| 37 11. Taking the product out of operation CAUTION Hot surface Minor or moderate personal injury ● The surface of the product may be so hot that it will cause burns or personal injury.
Multilift MD1, MDV | Fault finding the product| 38 12. Fault finding the product DANGER Electric shock Death or serious personal injury ● Switch off the power supply before you start any work on the product. Make sure that the power supply cannot be accidentally switched on.
Multilift MD1, MDV | Fault finding the product| 39 12.2 F002 Conditions: • The red LED is flashing. • The buzzer and the alarm symbol are on. • Display text: F002. • The symbol of the phase sequence is flashing.
Multilift MD1, MDV | Fault finding the product| 40 12.5 F117 • The red LED is flashing. • The buzzer and the alarm symbol are on. • Display text: F117. Cause Remedy The cable between the main board and the display is not con- Disconnect and reconnect the nected properly.
2. If F003 is not one of the latest faults, the sensor type could have accidentally been changed via the display or Grundfos PC Tool. Go to solution 2. 3. If the problem is still not solved, contact the nearest Grundfos sales company. Solution 1...
Multilift MD1, MDV | Fault finding the product| 42 12.9 EXTERN • The red LED is flashing. • The buzzer and the alarm symbol are on. • Display text: EXTERN. Cause Remedy Flooding outside the tank. The Find the source of the flooding and eliminate the problem.
Multilift MD1, MDV | Fault finding the product| 43 12.11 The pumps do not start • The power supply is switched on. • The selector switches are in position AUTO or ON. The display is off Cause Remedy The control-current fuse is blown.
Multilift MD1, MDV | Fault finding the product| 44 1. Check that the cable is connected properly at both ends. 2. If the problem is still not solved, replace the cable. Use an ethernet cable, RJ45. Related information • 9.2.2 Cleaning the pressure tube and hose 12.12 The pumps start randomly...
Multilift MD1, MDV | | 45 13. Technical data 13.1 Operating conditions Controller Ambient temperature during 0-40 operation [°C] Pump Ambient temperature [°C] SE: -20 to +40 SL: -20 to +30 Liquid temperature [°C] 0-40 For short periods up to 60...
This product or parts of it must be disposed of in an environmentally sound way. 1. Use the public or private waste collection service. 2. If this is not possible, contact the nearest Grundfos company or service workshop. Subject to alterations.
Page 47
GRUNDFOS Pumps (Hong Kong) Ltd. Turkey Telefax: +32-3-870 7301 Unit 1, Ground floor, Siu Wai Industrial Centre GRUNDFOS Pumper A/S GRUNDFOS POMPA San. ve Tic. Ltd. Sti. 29-33 Wing Hong Street & 68 King Lam Strømsveien 344 Belarus Gebze Organize Sanayi Bölgesi...
Need help?
Do you have a question about the Multilift MD1 and is the answer not in the manual?
Questions and answers