Operating The Product; Setting The Controller; Setting The Start Level; Setting The Rated Current - Grundfos Multilift MD1 Installation And Operating Instructions Manual

Hide thumbs Also See for Multilift MD1:
Table of Contents

Advertisement

8. Operating the product

8.1 Setting the controller

8.1.1 Setting the start level

When you switch on the controller for the first time, the startup wizard guides you through the nec-
essary settings. If you later want to change the start level, follow these steps:
1. Go to the settings menu.
2. Press OK.
3. Go to menu L_01.
4. Press OK.
5. Select the start level.
6. Press OK.

8.1.2 Setting the rated current

When you switch on the controller for the first time, the startup wizard guides you through the nec-
essary settings. If you later want to change the rated motor current, follow these steps:
1. Go to the settings menu.
2. Press OK.
3. Go to menu I_02.
4. Press OK.
5. Press arrow right or left to set the rated current according to the motor nameplate.
6. Press OK.

8.1.3 Setting the stop delay

1. Go to the settings menu.
2. Press OK.
3. Go to menu T_01.
4. Press OK.
5. Press arrow right or left to set the delay in seconds.
6. Press OK.

8.1.4 Setting the start delay

1. Go to the settings menu.
2. Press OK.
3. Go to menu T_02.
4. Press OK.
5. Press arrow right or left to set the delay in seconds.
6. Press OK.

8.1.5 Setting the alarm delay

1. Go to the settings menu.
2. Press OK.
3. Go to menu T_03.
4. Press OK.
5. Press arrow right or left to set the delay in seconds.
6. Press OK.
Select 450 mm if the low inlet is used.
Select 700 mm if the high inlet is used.
Select 450 mm if the inlet pipe height is between the two values.
The factory setting is 0.
Multilift MD1, MDV | | 32