INSTRUCTIONS PERTAINING
TO THE INSTALLER

General information

Warning: If the selector switch (1) is set on (
a few minutes each time the burner is
started. To get the burner to start
immediately, selector switch (1) can be
set to (0) and then again on (
waiting time does not occur if the selector
switch (1) is set to the (
symbol
.
The following explanations and technical instructions are addressed to
installers
and are intended to help ensure a faultless installation.
The boiler must be installed, adjusted and started for the first time by an
approved specialist.
The gas supply company's regulations, as well as the local building
regulations, must be observed (The Gas Regulations and the Building
Regulations)
The boiler can be connected to any type of heating surfaces, radiators
or convectors, in both single and double pipe systems. The pipe
diameters must be calculated in the normal way, taking into account the
characteristics of the available heating surfaces, as well as the water
quantities and pump pressure indicated on page 31.
To ensure satisfactory and safe operation of the boiler, we recommend
that the boiler be checked every other year by an authorised servicing
firm.
Packaging (plastic bags, polystyrene, etc.) must not be left within
children's reach as they are a potential source of danger.
Instructions prior
to installation
The boiler heats water to a temperature below boiling point at normal air
pressure. It must be connected to a heating system which corresponds to
its characteristics and output. The following operations must be carried
out before installation of the boiler:
a) All of the appliance's pipes must be flushed out to remove any threading
and welding deposits and also any remains of solvent
b) Check that the boiler is intended for operation with the type of gas
available. This can be read from the inscriptions on the packaging and
from the rating plate on the boiler.
c) The boiler may be installed in a cupboard, the corner of a room and wall
rececesses etc., provided that a minimum clearance of 20 mm is
maintained between the boilder and the fixed side-wall. In addition,
allowance must be made for the required height for installation of the
flue system and also for any servicing or cleaning of dirt collectors
below the boiler.
d) The boiler is usually very quiet, but the pump and fan may be annoying.
Account should be taken of any noise nuisance from the boiler when it
is installed next to or in a living room. The best position will be on an
external wall or other heavy wall. The wall must be able to bear the
weight of the boiler with water and pipes etc.
) there will be a wait of
). This
) DHW
INSTALLATØREN
Almene anvisninger
Vigtigt: Hvis omskifteren (1) befinder sig i position (
De følgende forklaringer og tekniske vejledninger henvender sig til
installatøren og skal medvirke til en perfekt installation.
Installation, indstilling og første start af kedlen må kun gennemføres
af en godkendt fagmand.
Gasforsyningsselskabets forskrifter, såsom de lokale byggeregler,
skal overholdes (Gasreglementet og Bygningsreglementet).
Kedlen kan bruges med enhver art varmeflader, radiator eller konvektor
såvel i 1-strengs- som i 2-strengs anlæg. Rørenes diameter skal
beregnes på normal måde, hvorved de forhåndenværende varmefladers
egenskaber, såvel som de på side 31 anførte vandmængder og pumpetryk
tilgodeses.
For at sikre en upåklagelig og sikker drift af kedlen anbefales det, at
kedlen hvert andet år bliver kontrolleret af et autoriseret servicefirma.
Emballage (plastikposer, polystyrol osv.) må ikke være tilgængelig for
børn, da det repræsenterer en potentiel farekilde.
Anvisninger før installation
Kedlen opvarmer vand til en temperatur under kogepunktet ved alm.
lufttryk. Den skal tilsluttes et varmesystem, der svarer til dens egenskaber
og ydelse. Inden installation af kedlen skal følgende gennemføres:
a) Alle anlæggets rørledninger skal skylles for at fjerne gevind- og
svejserester, samt rester af opløsningsmidler.
b) Det skal kontrolleres, om kedlen er beregnet til drift med den til
rådighed stående gasart. Dette kan aflæses af påskriften på emballagen
og af kedlens typeskilt.
c) Kedlen kan indbygges i skabe, rumhjørner og murnicher m.v., såfremt
der holdes en afstand på min. 20 mm mellem kedlen og faste sidevægge.
Der skal endvidere tages hensyn til fornøden højde til montering af
aftrækssystemet samt eventuel betjening og rensning af snavsamler
under kedlen.
d) Kedlen er normalt meget støjsvag, men pumpe og ventilator kan dog
virke generende. Der bør tages højde for eventuelle støjgener fra
kedlen, når den opsættes op til eller i et beboelsesrum. Bedste placering
vil være på en ydervæg eller anden tung væg. Væggen skal kunne bære
vægten af kedlen med vandindhold og rør m.v.
9
921.968.2.00.02.010702
VEJLEDNING TIL
enhver start af brænderen opstå en
ventetid på nogle minutter. For at opnå,
at brænderen starter med det samme, kan
omskifteren (1) stilles på (0) og derefter
igen tilbage til (
opstår ikke, hvis omskifteren (1) er
indstillet på
9803300300
), vil der ved
). Denne ventetid
DHW-symbol.