Installation Of The Outside Probe; Installation Af Udeføleren - Baxi NUVOLA 28 Fi Installers And Users Instructions

High efficiency, fast-heating gas boilers with balanced flue for wall-mounting
Table of Contents

Advertisement

Installation of the outside
probe
The outside probe is temporarily connected by means of a short cable and
is placed behind the boiler controls during transport.
Replace the short, temporary cable with a cable appropriate to the final
position. (Maximum cable length 20 m, minimum 0.5 mm
Installation and connection
The outside probe must be installed on an outside wall of the building
that you intend to heat, taking care to comply with the following
recommendations:
install on a wall facing north or north-east (away from direct sunlight);
if possible, avoid fixing the probe to a wall where damp or mold tends
to form (since these are indications of a thermal bridging effect);
make sure that the wall you choose is a wall with a thickness sufficient
to ensure an adequate thermal insulation (e.g., avoid attaching the
probe to a metal wall or a partition wall);
avoid installing the probe in the vicinity of any fans, steam or air
outlets from rooms or flues (it is important to make sure that the outside
temperature registered by the probe is not affected by any unwanted
influences).
The probe is fixed to the wall with the aid of two 5x25 anchoring screws.
The wire for connecting the probe to the boiler must be fixed to the terminal
board, taking care to lock it in the watertight cable holder (remember to tighten
the screw properly to avoid any damp in the air getting through the opening).
The connection to the boiler must be made using a two-pole cable with a
cross section of at least 0.5 mm
It is not necessary to comply with the polarity of the cable for the
connection of the probe to the boiler.
Wall fixture
1 - Unscrew the plastic cover by turning it anticlockwise to access the
terminal board and thefixing holes (fig. 4).
2 - Identify a suitable position for fixing the probe to the wall and mark the
distance between the centres for the holes (fig. 5).
3 - Unscrew the nut on the cable holder, insert the cable for connecting the
probe to the boiler and screw the two copper wires onto the terminal board
(there is no need to identify the polarity) (fig. 6). Then screw down the cable
holder nut completely and put the cover back in place on the container.
Heating curve
NOTE: each heating curve shown in the graph coincides with a position
of the potentiometer P1-Kt on the printed circuit board. You can therefore
set the flow temperature best suited to the needs of the system and user,
depending on the outside temperature.
X = OUTSIDE TEMPERATURE
Y = FLOW TEMPERATURE
Connection of outside probe
Connect the outside probe to terminals 1 and 2 on the M1 terminal block
on the printed circuit board, which is located on the inside of the cover of
the boiler controls (see figs. 4-8).
Figure 4 - Figur 4
2
).
2
and not exceeding 20 m long.
Installation af udeføleren
Udeføleren er midlertidigt forbundet med en kort ledning og placeret bag
kedelstyringen under transporten.
Den korte, midlertidige ledning erstattes af ledning der passer til den
endelige placering. (Max ledningslængde 20 m. minimum 0,5 mm
Installation og tilslutning
Udeføleren skal monteres på ydersiden af bygningen, som skal opvarmes,
og man skal sørge for, at følgende bliver overholdt:
Montering foretages på en nord- eller nordøstvendt mur (væk fra
direkte sollys).
Om muligt skal det undgås at montere føleren på en mur med tendens
til fugt- eller mugdannelse (da disse indikerer kuldebroeffekt).
Sørg for, at den valgte mur har en tykkelse, der er tilstrækkelig til at
sikre passende termisk isolering (undgå f.eks. at fæstne føleren til en
skillevæg eller en væg af metal).
Undgå at montere føleren i nærheden af oplukkelig vindue eller røg-
og ventilationsåbninger (det er vigtigt at sikre sig, at
udendørstemperaturen, som registreres af føleren, ikke bliver
uhensigtsmæssigt påvirket).
Føleren fastgøres til muren ved hjælp af to 5x25 forankringsskruer.
Forbindelsesledningen fra føleren til kedlen skal fastgøres til klembrættet,
og den skal gemmes i den vandtætte kabelskinne (husk at stramme skruen
godt for at undgå, at der kommer fugt eller luft gennem åbningen).
Tilslutningen til kedlen skal foretages ved hjælp af et topolet kabel med et
tværsnit på mindst 0,5 mm
Det er unødvendigt at overholde polariteten af kablet i forbindelse med
tilslutningen af føleren til kedlen.
Fastgørelse til muren
1 - Skru plasticdækslet af ved at dreje det mod uret for at få adgang til
klembrættet og monteringshullerne (fig. 4).
2 - Find en passende placering til føleren på muren, og markér afstanden
mellem hullernes midtpunkter (fig. 5).
3 - Skru møtrikken på kabelaflastningen ud, indfør kablet, som skal
forbinde føleren med kedlen, og skru de to ledninger fast til klembrættet
(det er unødvendigt at identificere polariteten) (fig. 6). Spænd
kabelaflastningen i bund, og fastgør atter dækslet til beholderen.
Varmekurve
BEMÆRK: Hver varmekurve vist på grafen falder sammen med en position
på potentiometeret P1-Kt på printkortet. Man kan således indstille den
fremløbstemperatur, der passer bedst til brugerens og anlæggets behov,
afhængigt af udendørstemperaturen.
X = UDENDØRSTEMPERATUREN
Y = FREMLØBSTEMPERATUREN
Tilslutning af udeføler
Udeføleren tilsluttes klemme 1 og 2 i klemrækken M1 på print kortet, der
er placeret på indersiden af kedelstyringens dœksel (se fig. 4-8).
Figure 5 - Figur 5
24
921.968.2.00.02.010702
2
og en længde på højst 20 m.
Figure 6 - Figur 6
2
).