"Horizontal" flue pipes must be installed with a fall of at least a 5 ‰
towards the condensation trap.
NOTE: There are criteria for the distance from an external flue pipe to
flammable materials.
* 25 mm mineral wool insulation is not supplied by BAXI.
NB:With flue lengths over 3 metres in the chimney, we recommend fitting
of a condensation trap.
In the case of installation in a disused chimney, a servicing / cleaning
door must be fitted in the chimney jamb, allowing dismantling of the
float in the lower part for cleaning / servicing.
SPLIT FLUE IN CONNECTION WITH EXISTING
DISUSED CHIMNEY
S1 and S2 System
Where indicated by the conditions, use the SPLIT flue, which means that
the air is taken in via one pipe and the flue gas is directed out above a
chimney / roof in another pipe.
The connecting set for "flue/air via a chimney" consists of:
1 connecting set Ø 80
In addition, the following must be used:
Air intake and cover
Cap for the chimney
Straight pipe for air or flue gas (use a rust-resistant pipe for flue gas, an
aluminium pipe for air)
Maximum total length of split flue = (10 + 10) m minus 1 m for each
90° bend (0.5 m for each 45° bend)
15°, 30°, 45° or 90° bend (use a rust-resistant pipe for flue gas, an
aluminium pipe for air)
Silicone
If necessary, pipe clamps for flue pipe and air pipe
If necessary, ceiling flange Ø 80
If necessary, condensation trap
Installation of SPLIT in a typical chimney
Fit the split connecting set to the boiler as
shown elsewhere in these instructions.
Air intake (Use an aluminium pipe for air)
S
:
Secure air grating to the outside of the wall
1
using the Rawlplugs and rust-resistant
screws provided. If necessary, seal around the
grating with silicone.
S
:
Air from an unused loft of at least 70 m
2
Use the air grating provided on the top of
the pipe.
Flue (A rust-resistant pipe must be used for flue
gas.)
The chimney must be disused and must be very
carefully cleaned.
Minimum diameter of chimney Ø 130
Maximum total length of the split flue = (10 + 10)
m minus 1m for each 90° bend (0.5 m for each
45° bend)
Use silicone or similar for a water-tight joint
Screw the top section securely on top of the
chimney.
Attach the flue outlet pipes to the top insulated flue pipe with cover, and
then lower all of the pipes into the chimney. (If necessary, secure the
joints with self-tapping, rust-resistant screws or pop rivets (not pro-
vided).)
Mount the drip edge on the "Insulated flue pipe with cover"
The pipe is taken from the flue outlet pipe in the chimney to the boiler.
OBS: Der er afstandskrav fra udvendig aftræksrør til brændbart matr.
NB: Ved aftrækslængde over 3 meter i skorstenen anbefales installation
Hvor forholdene taler herfor anvendes SPLIT aftræk hvorved forstås at
luften tages ind i et rør og røggas ledes ud over skorsten/tag i et andet.
Tilslutningssæt til "Aftræk/luft via skorsten" består af:
1 stk. tilslutningssæt Ø80
Desuden skal bruges:
Insulated flue pipe with cover
Isoleret røggasrør m/hætte
Drip edge
Drypkont
Cap for chimney
Top til skorsten
Pipe Ø80 (rust-resistant)
Rør Ø80 (rustfri)
3
.
Bend (Alu.)
Silicone
Bøjning (Alu.)
Silicone
Wall grating
Murrist
18
921.968.2.00.02.010702
evt. slutte min. 100 mm herfra.
"Vandrette" aftræksrør skal føres med min. 5 promille fald mod
kondensfanget.
25 mm mineraluldsisolering medleveres ikke fra BAXI.
af kondensfang
Ved montage i afmeldt skorsten skal der i skorstensvangen etableres
en service-/renselem, der muliggør afmontering af svømmeren i
underparten for rensning/service.
SPLIT AFTRÆK I FORBINDELSE MED EKSISTERENDE
AFMELDT SKORSTEN
System S1 og S2
Luftindtag og hætte
Top til skorsten
Lige rør til luft eller røggas (Til røggas skal anvendes rustfri rør, til luft
anvendes aluminiumsrør)
Max totallængde af splitaftræk = (10+10)m minus 1 m for hver 90 °
bøjning (0,5 m pr. 45 ° bøjning)
Bøjning 15º, 30º, 45 ° eller 90 ° (Til røggas skal anvendes rustfri rør, til
luft anvendes aluminiumsrør)
Silikone
Evt. rørbærer for røgrør og luftrør
Evt. loftkrave Ø80
Evt. kondensfang.
Montage af SPLIT i eks. skorsten
på kedlen som anført andetsteds i denne
instruktion.
Luftindtag
aluminiumsrør)
S
rawlplug og rustfri skruer udvendig på
mur. Der tætnes evt. omkring rist med
silikone.
S
70 m
90° bend Ø80 (rust-resistant)
røret.
Bøjning 90 ° Ø80 (rustfri)
Condensation trap
Kondensfang
Røgaftræk (Til røggas skal anvendes
Wall bushes
Murbøsninger
rustfri rør)
Pipe Ø 80 (Alu.)
Skorstenen skal være afmeldt og skal være
Rør Ø 80 (Alu.)
renset meget omhyggeligt.
Vertical connecting set
Minimum diameter af skorsten Ø 130
Split tilslutningssæt
Max totallængde af splitaftræk =
(10+10)m minus 1 m for hver 90 ° bøjning
(0,5 m pr. 45 ° bøjning)
Benyt silikone el. lign. for vandtæt samling.
Topstykket skrues forsvarligt på top af skorsten.
Røgaftræksrørene monteres på øverste isolerede røggasrør m. hætte,
hvorefter alle rørene sænkes ned i skorstenen. (Samlingerne sikres evt.
med selvskærende rustfri skruer eller popnitter (medfølger ikke))
Drypkant spændes på "Isoleret røggasrør m/hætte"
Rør føres fra røgaftræksrør i skorsten til kedel.
Split tilslutningssættet monteres
(Til luft anvendes
:
Luftrist fastgøres med de med flg.
1
:
Luft fra uudnyttet tagrum på min.
2
3
. Medflg. luftrist anvendes ovenpå

Advertisement

Table of Contents
loading

Table of Contents