Baxi NUVOLA 28 Fi Installers And Users Instructions page 12

High efficiency, fast-heating gas boilers with balanced flue for wall-mounting
Table of Contents

Advertisement

S2 Air from unused loft of at least 70m
Maximum total length (air + flue gas) is (10 + 10 m).
S3 Air from unused loft of at least 70m
the roof
S4 Air from external wall-flue pipe taken vertically above the roof
S5 Horizontal split with air and flue pipe taken side by side to an external
wall.
NOTE: The air intake must be taken from the open air or from a ventilated
3
loft of at least 70 m
.
See following pages for additional data.
DISTANCE REQUIREMENTS – AIR INTAKE / FLUE OUTLET
It is necessary to comply with the Gas Regulations concerning
distances from woodwork and meter cupboards etc.
BALANCED FLUE – HORIZONTAL or VERTICAL DOUBLE PIPE
There are no distance requirements from external double pipe to woodwork
(for flue solution L3, see distance requirements for split solution).
In addition, the following distance requirements must be observed:
HORIZONTAL – positioning of air intake / flue outlet
From vertical outlet pipe
From internal or external corners
From wall opposite (facing the air intake / flue outlet)
From another air intake / flue outlet opposite
Vertically from another air intake / flue outlet on the same wall
Horizontally from another air intake / flue outlet on the same wall
VERTICAL - positioning of air intake / flue outlet
Vertical above the roof surface with the following distance
requirements:
Distance measured perpendicular to the roof surface
Distance to vertical wall (chimney)
Height above chimney (with pipe taken through the chimney) 300
Height above flat roof
SPLIT FLUE – distance requirements
Where indicated by the conditions, a split flue may be used, i.e. air intake
and flue pipe are each carried in its own pipe. Bends and pipes should be
ordered in accordance with the local conditions, but they are subject to
the following limitations:
Max. total length of the split flue (air pipe + flue pipe) = 20 m minus 1 m
for each 90° bend – (2 x 45° bends = 1 x 90° bend).
Distance requirements from flammable materials and insulation
The distance from flammable materials must be as laid down in the Gas
Regulations regarding flue ducts (section 5.5). These say among other
things: On all sides, there must be a distance of at least 50 mm from the
outer edge of the flue pipe to flammable materials. The flue pipe MUST
be insulated with a minimum of 25 mm mineral wool from and including
the first floor, up to and including the end above the roof.
In addition, the following distance requirements must be observed:
SPLIT FLUE – HORIZONTAL or VERTICAL
Positioning of air intake
Height above ground
Vertically and horizontally from another balanced flue
Horizontally from regulator cabinet
Vertically from regulator cabinet
From ventilation opening
3
, flue pipe taken via the chimney
3
, flue pipe taken vertically above
Min. distance (mm)
75
500
2000
1200
500
500
Min. distance (mm)
300
500
750
Min. distance (mm)
300
800
200
1000
500
921.968.2.00.02.010702
S2 Luft fra uudnyttet tagrum på mindst 70 m
skorsten
Maksimal samlet længde (luft+røggas) er (10 + 10m).
S3 Luft fra uudnyttet tagrum på mindst 70 m
tag.
S4 Luft fra ydervæg-røggasrør ført lodret over tag.
S5 Vandret split med luft- og røggasrør ført ved siden af hinanden til
ydervæg.
OBS! Luftindtag skal tages fra det fri eller fra ventileret loftrum min. 70 m
Yderligere data se følgende sider.
AFSTANDSKRAV - LUFTINDTAG/RØGAFGANG
Man skal rette sig efter Gasreglementets krav vedr. afstande til træværk
og måleskabe etc.
BALANCERET AFTRÆK - VANDRET eller LODRET DOBBELTRØR
Der er ingen afstandskrav fra udv. dobbeltrør til træværk. (Ved
aftræksløsning L3 se afstandskrav til splitløsning)
Desuden skal følgende afstandskrav respekteres:
VANDRET - Placering af luftindtag/røgafgang
Fra lodrette afløbsrør
Fra indvendige eller udvendige hjørner
Fra væg overfor (imod luftindtaget/røgafgangen)
Fra anden luftindtag/røgafgang overfor
Lodret fra anden luftindtag/røgafgang på samme væg
Vandret fra anden luftindtag/røgafgang på samme væg
LODRET - Placering af luftindtag/røgafgang
Lodret over tagflade med følgende afstandskrav: Min. afstand (mm)
Afstand målt vinkelret på tagfladen.
Afstand til lodret væg (skorsten)
Højde over skorsten (med rør ført gennem skorsten)
Højde over fladt tag
SPLITAFTRÆK - Afstandskrav
Hvor forholdene taler for det kan der bruges splitaftræk, dvs. luftindtag
og røgrør føres i hvert sit rør. Bøjninger og rør bestilles efter de stedlige
forhold, der er dog den begrænsning at:
Max. totallængde af splitaftræk (Luftrør + røgrør) = 20 m minus 1 m for
hver 90 ° bøjning - (2 stk 45 ° = 1x90 ° bøjning)
Afstandskrav til brændbart matr. og isolering.
Afstand til brændbart matr. skal være som Gasreglementet foreskriver vedr.
aftrækskanal (afsnit 5.5) Det vil bl.a. sige:
Der skal overalt være en afstand på mindst 50 mm fra yderkant røgrør til
brændbart materiale.
Aftræksrøret SKAL isoleres med min. 25 mm mineraluld fra og med første
etageadskillelse til og med afslutning over tag.
Desuden skal følgende afstandskrav respekteres:
SPLITAFTRÆK VANDRET eller LODRET
Placering af luftindtag
Højde over terræn
Lodret og vandret fra andet balanceret aftræk
Vandret fra regulatorskab
Lodret fra regulatorskab
Til ventilationsåbning
12
3
, røggasrør ført gennem
3
, røggasrør ført lodret over
3
Min. afstand (mm)
75
500
2000
1200
500
500
300
500
300
750
Min. afstand (mm)
300
800
200
1000
500

Advertisement

Table of Contents
loading

Table of Contents