Table 11 Charger Settings Menu Description
Item
Description
Sets the maximum time spent in the absorption
Absorb
stage, before transitioning to float or no float.
Time
NOTE: The Absorb Time setting resets to its
default value of 180 minutes when the Battery Type
is changed except when changing to Custom
Settings. In Custom Settings, the Absorb Time
setting will not reset to its default value.
Selects the battery temperature charging
Default
compensation if a battery temperature sensor is not
Batt
installed. In the absence of a battery temperature
Temp
sensor, the charger uses one of three settings: Cold
(5 °C/41 °F), Warm (25 °C/77 °F), or Hot (40 °C/
104 °F).
97-0019-01-01
Configuring the Freedom SW using the SCP

Battery Charger Functions

When AC power is available, the Freedom SW can operate as
a battery charger. Different battery types and chemistries
require different charging voltage levels. Not charging
batteries at the required levels can shorten battery life or
damage the batteries. The Freedom SW is configured at the
factory to work with the battery types recommended for
inverter applications. If the default settings do not work for
your specific installation, you can adjust the charge stage
settings (as recommended by the battery manufacturer) on the
Custom (Battery) Settings menu (see page 62).
NOTE:
This information is provided for guidance only. Variations in
battery chemistry and site-specific environmental considerations mean
that you should consult your system designer or battery manufacturer for
specific recommendations for appropriate battery voltage and current
settings.