8 REVIEWING BATCH DATA - MODEL T (continued)
8.2 BATCH READINGS (Batch/Review Batch/Readings)
Displays the reading value together with date and time stamp for each
individual reading in the batch.
Note: When using 'Mean (xbar) Reading Mode' - see Section 6.2 on page en-7, only
the average of each set of three readings is saved in the batch memory and
displayed in the batch reading review screen.
 
Press the
softkeys to scroll through
the readings and  to move to the next
information screen.
Readings outside any enabled limits for
the batch are displayed in red with the
appropriate limit icon to the left of the
reading, (
) if the reading is below the
low limit and (
8.3 BATCH GRAPH (Batch/Review Batch/Batch Graph)
Allows the user to view the readings within the batch as a column bar
graph.
Up to five horizontal axes are displayed
representing different values / statistics
as follows:
Highest reading in the batch (Hi:)
Lowest reading in the batch (Lo:)
Average reading for the batch (
a
Low Limit (
a
High Limit (
Note: When using 'Mean (xbar) Reading Mode' - see Section 6.2 on page en-7, only
the average of each set of three readings is saved in the batch memory and
displayed on the batch graph.
If limits were not set and enabled, the readings are displayed as white
vertical bars. If limits were set and enabled, readings are displayed as
white bars if within set limits or red; if outside set limits.
a
When set and enabled.
c
For batches of more than one reading.
www.elcometer.com
) if above the high limit.
)
)
c
c
c
:)