About Sunvts Software; What To Do - Sun Microsystems Enterprise 220R Service Manual

Sun microsystems server user manual
Hide thumbs Also See for Enterprise 220R:
Table of Contents

Advertisement

and off (no testing). The system runs the appropriate level of diagnostics based on
the setting of the OpenBoot PROM variable diag-level.
The default setting for diag-level is min.
If your server is set up without a local console or terminal, you will need to set up a
monitor, console, or terminal before setting the diagnostic level. See Section 2.10
"About Communicating With the Server" on page 73.
7.7.2

What to Do

Note -
Power-On/Off position.
1. With the keyswitch in the Power-On/Off position, press the Break key on your
alphanumeric terminal's keyboard, or enter the Stop-a sequence on a Sun
keyboard.
To enter the Stop-a sequence, press the Stop key and the a key simultaneously.
The ok prompt is displayed.
2. To set the diag-level variable, type the following:
The value can be off, min, or max. See Section 7.5.2 "Configuration Variable" on
page 194 for information about each setting.
7.8

About SunVTS Software

SunVTS
exerciser for verifying the configuration and functionality of hardware controllers,
devices, and platforms. You can run SunVTS using any of these interfaces: a
command-line interface, a TTY interface, or a graphical interface that runs within a
windowed desktop environment.
SunVTS software lets you view and control a testing session over modem lines or
over a network. Using a remote system, you can view the progress of a SunVTS
testing session, as well as change testing options and control all testing features of
another system on the network.
206
Sun Enterprise 220R Server Service Manual
Perform this procedure with the power on and the keyswitch set to the
ok setenv diag-level value
TM
, the Sun Validation and Test Suite, is an online diagnostics tool and system
January 2000, Revision A

Advertisement

Table of Contents
loading

Table of Contents