electrical power going to the Receiver module and a fresh set of batteries in the transmitter. Now switch the slide switch to
the middle [REMOTE] position and then push the small pushbutton to begin programming. Bring the transmitter close to
the receiver and then press the power button [ ] on the transmitter. An audible beep will sound to indicate the system is
programmed and ready to be used.
NOTE: The Remote Receiver module can also be located outside
of the appliance to a maximum of 6ft away installed in a certified
deep wall switch electrical box (2-3/4" depth). For this
configuration an extension wiring harness (P/N: 1001-P904SI) is
required.
Electrical Supply in Series: The entire IPI system can be powered by a
single power source (i.e. by the AC Adapter). This is advantageous if you
do not want to supply extra batteries. To achieve this simply connect the
AC Adapter into the Remote Control wiring harness instead of the main
IPI harness. From the Remote wiring harness, use its male plug-in
connector and connect it to the female plug-in in the main IPI harness.
Now the circuit is complete. So the way it works is that electrical power is
supplied to the Remote Receiver module and then proceeds to the Main
IPI module. Furthermore, note that a Backup Battery Pack is not required
in this configuration. Instead, batteries in the Remote Receiver act as the
backup supply.
Junction Box Location
The electrical junction box must be located on the outside of the appliance near the bottom as shown in the illustration to
the right. Be sure to follow local electrical codes when install the junction box.