Chapter 4
Troubleshooting Procedures
Activity TE2:
Hardware Failure
Activity TE3:
Network Test Failure
Activity TE4:
Network Test was
Aborted or the net
Command Failed
Activity TE7: Booted
Wrong Image
4-10
Remote Annex 4000 Hardware Installation Guide
The ROM diagnostics detected a Remote Annex 4000 hardware
problem requiring service. Call technical support.
The Ethernet interface did not pass a simple transceiver loopback test.
First, verify that the Ethernet port either is connected to an Ethernet
transceiver or has a loopback plug installed. If the test still fails, type
q on the console to access the ROM Monitor prompt. See net on page
3-22 for more information on isolating the problem.
The Ethernet loopback test failed and the user typed q to access the
ROM Monitor prompt.
The Remote Annex 4000 loaded an inappropriate image. Pressing the
Reset switch clears this error. The Remote Annex 4000 loads
inappropriate images if one of the following operator errors occurs:
Configuring the Remote Annex 4000 with an incorrect file
name, or renaming or copying the image file to the wrong
name.
Supplying the wrong name to the boot command.