Personality Function; Foreseeable Misuse Of The Enabling Device - Bosch REXROTH IndraControl VEH 30.2 Project Planning Manual

Hand-held terminal
Table of Contents

Advertisement

78/109
Bosch Rexroth AG
Pin Assignments of the IndraControl VEH 30.2
7.2

Personality Function

7.3

Foreseeable Misuse of the Enabling Device

In most cases the plant has a continuous Ethernet network. However, the as‐
signment of M-keys, stop button or enabling button is assigned to one con‐
trol.
The stop pushbutton and the enabling device are hard-wired to the VAC 30.2
connection module. The network data of the IndraControl VEH 30.2 as well
as the IP address of the control are saved in the VAC 30.2 connection mod‐
ule via the memory function.
In this way different sections of a plant can be visualized by means of one
IndraControl VEH 30.2 via several IndraControl VAC 30.2 connection mod‐
ules. With each change of the plug-in location the IndraControl VEH 30.2
gets e. g. a new target IP address or a UDP address.
The following functionality is in preparation:
As far as IndraWorks is concerned, the intelligent connection
module IndraControl VAC 30.2 is intended to serve as wild card
for a firmly projected operating device. The application is filed in
the IndraControl VEH 30.2, on a network server or on the control,
see IndraWorks VCH configuration dialogs.
The IndraControl VEH 30.2 applies the network settings that are read out
from the VAC 30.2 connection module after every restart. These settings can
be adjusted in the Rexroth Settings, see
These settings are saved in the IndraControl VAC 30.2 connection module.
If
the
data
is
successfully
IndraControl VAC 30.2, this configuration always takes priority. If no configu‐
ration data is found in the IndraControl VAC 30.2, the IndraControl VEH 30.2
device starts with the internally saved settings.
Impermissible fixing of the enabling button in the enabling position by using
auxiliary means is considered as foreseeable misuse. Such foreseeable mis‐
use can be prevented.
The following measures causing the stop of the machine in the manual mode
are recommended:
Inquiry of the enabling device when turning on the machine or plant and
inquiry of the enabling device when changing the operation mode from
automatic to manual (the enabling device must not be in the enabling
position).
The enabling device must be released within a defined period and push‐
ed into the enabling position again. The length of the period must be de‐
fined according to the requirements of the activity.