X2.1: Stop Pushbutton; X2.2: Enabling Button - Bosch REXROTH IndraControl VEH 30.2 Project Planning Manual

Hand-held terminal
Table of Contents

Advertisement

DOK-SUPPL*-VEH*30.2***-PR03-EN-P
Rexroth IndraControl VEH 30.2 Hand-Held Terminal
7.1.5

X2.1: Stop Pushbutton

Pin Assignment
7.1.6

X2.2: Enabling Button

Pin Assignment
Pin
X2.1 pin1
X2.1 pin2
X2.1 pin3
X2.1 pin4
Tab.7-3:
Pin assignment of the stop button X2.1
DANGER
The circuit of the stop button or emergency stop button might be operated
with a maximum of 30 V and must be protected with a 2-A-fusible cut-out.
Pin
X2.2 pin1
X2.2 pin2
X2.2 pin3
X2.2 pin4
Tab.7-4:
Pin assignment of the enabling button X2.2
DANGER
The circuit of the enabling device might be operated with a maximum of 30 V
and has to be protected with a 2-A-fusible cut-out.
Bosch Rexroth AG
Pin Assignments of the IndraControl VEH 30.2
Signal name
Stop pushbutton 1 IN
Stop pushbutton 1 OUT
Stop pushbutton 2 IN
Stop pushbutton 2 OUT
Risk of injury due to malfunction of the stop
button or emergency stop button.
Signal name
Enabling device 1 IN
Enabling device 1 OUT
Enabling device 2 IN
Enabling device 2 OUT
Risk of injury due to malfunction of the ena‐
bling button.