Ec Declaration Of Conformity; Dguv Test Certificate; Ul And Csa Certified; Wear Parts - Bosch REXROTH IndraControl VEH 30.2 Project Planning Manual

Hand-held terminal
Table of Contents

Advertisement

48/109
Bosch Rexroth AG
Technical Data
4.14

EC Declaration of Conformity

4.15

DGUV Test Certificate

4.16

UL and CSA certified

4.17

Wear Parts

LED backlight
trol cabinet) to the control (continuous connection from the hand-held termi‐
nal to the control). When using the appropriate connection module and a
shielded cable for the data line from the connection module to the control, the
continuous, high frequency compatible connection of the shield from the
IndraControl VEH 30.2 to the control is guaranteed.
For connecting an Ethernet communication interface to a control system, a
CAT6-compatible connecting cable must be used. Cables carry the Ethernet
signals to a suitable connector (RJ-45) and thereby produce a continuous
shielding connection and also the required characteristic impedance of the
cable.
The EC Declaration of Conformity is filed in
103.
The part "enabling control device" was tested according to GS-ET-22 princi‐
ples of testing. GS-ET-22 is harmonized with the 2006/42/EC requirements.
The test certificate confirms the requirements of the GS-ET-22 for the ena‐
bling device integrated in the device. The certificate number is ET 11030.
The devices of the IndraControl VEH 30.2 product family are certificated ac‐
cording to
UL508 (Industrial Control Equipment) and
C22.2 no. 142-M1987 (CSA)
UL file no. E210730
However, there can be combinations or stages of expansions with limited or
missing certification. Therefore verify the certification by using the UL label on
the device.
To guarantee an UL- and CSA-compliant operation, the following
conditions have to be fulfilled:
Use only insulated copper wire suitable for at least 60/75 °C.
NOTICE
The UL- and CSA- marking is only valid for the device in its delivery status.
After having modified the device the UL and CSA compliance must be veri‐
fied.
The LED backlight is a wear part that is not subject to warranty. The LED
backlight has a limited service life. The service life is exceeded if the back‐
light produces only 50 % of its original brightness. According to the manufac‐
turer the service life of the display is:
DOK-SUPPL*-VEH*30.2***-PR03-EN-P
Rexroth IndraControl VEH 30.2 Hand-Held Terminal
chapter 13 "Appendix" on page
Loss of UL and CSA compliance due to
changes on the device.